Box steel column, groove weld, fillet weld, local buckling, weld leg size, overlap length, energy absorptionAbstract
The local buckling has always been known as an undesirable and destructive phenomenon in steel
structures. Thus, it is necessary to identify the effective factors in local buckling of the steel box column. Currently, box columns are generally fabricated by welding plates using fillet or groove welds with various manufacturing patterns, in terms of weld leg size and the overlap length of the plates. Hence, the evaluation of these patterns and also the control of local buckling in built sections seem to be essential. In this research, a variety of columns with different welding patterns, including groove and fillet welds with various overlap values and weld legs are numerically modeled and their local buckling behavior is studied in the finite element domain by using ABAQUS software. A suitable welding pattern is proposed by assessing the energy absorption, as well as stress distribution, stress concentration and finally local buckling in steel box section columns. The obtained results indicate that, the sections fabricated utilizing groove welds, have the best nonlinear performance. And also a suitable implementation of fillet welds to fabricate steel box columns is to consider 20% overlap length and 80% weld leg size to plate thickness as this model subject to small amount of local buckling. This model has shown less than 6% reduction in plastic capacity and energy absorption in comparison with groove welding. Another method is to use 50% for both overlap length and weld leg size to plate thickness. This model has shown less than 8% reduction in plastic capacity and energy absorption in comparison with groove welding. In addition, unsuitable implementation of fillet welds especially with small overlaps and weld leg sizes has shown a 12.5% reduction in plastic capacity and energy absorption, compared to groove welding
References
ABAQUS Standard User’s Mmanual, (2012), Version 6.10.1, New York, USA.
ANSI/ASIC 360-10 (2010). Specification for Structural Steel Buildings. American Institute of
Steel Construction, Chicago, IL.
Chiew, S., Lee, S. and Shanmugam, N. (1987) Experimental research of thin-walled steel box
column, Structural Engineering, 113(10): 2208-2220.
Cuong, B. (2013) Buckling of thin-walled members analyzed by Mindlin-Reissner finite strip,
Structural Engineering and Mechanics, 48 (1): 77-91.
Hashemi, S., Vaghefi, M., Hemmat, M. and Masihzadeh, A, (2016) Comparison the capacity of
box steel columns, fabricated with groove and fillet welds, International Journal of Steel
Structures, 16(2): 373-382.
Iranian National Steel Structural Building Code (2012), Design and Implementation of Steel
Structures, Iran Department of Housing and Urban Development, Tehran, Iran.
Migita, Y. and Fukumoto, Y. (1997) Local buckling behavior of polygonal sections,
Constructional Steel Research, 41(2-3): 221-233.
Moradi, M. and Arwade, S. (2014) Improving buckling response of the square steel tube by using
steel foam, Structural Engineering and Mechanics, 51(6): 1017-1036.
Mulligan, G.P. and Pekoz, T. (1984) Analysis of Locally Buckled Thin-Walled Columns,
Seventh International Specialty Conference on Cold-Formed Steel Structures, St. Louis,
Missouri, U.S.A.
Ostapenko, A. (1977) Local buckling of welded tubular columns, Thin-Walled Structures, 40(2):
–123.
Povlocic, L., Froschmeier, B., Kuhlmann, U. and Beg, D. (2010) Slender thin-walled box
columns subjected to compression and bending, Journal of Civil Engineering and
Management, 16(2): 179-188.
Richard Liew, J.Y., Shanmugam, N.E. and Lee, S.L. (1988) Local buckling of thin-walled steel
box columns, Thin-Walled Structures, 8(2): 119–145.
Seif, M. and Schafer, B.W. (2010) Local buckling of structural steel shapes, Constructional Steel
Research, 66(10): 1232–1247.
Wang, Y., Li, G., Chen, S., Sun, F. (2014) Experimental and numerical study on the behavior of
axially compressed high strength steel box-columns, Engineering Structures, 58:79–91.
Shen, H. (2012) Ultimate capacity of welded box section columns with slender plate elements,
Steel and Composite Structures, 13(1): 15-33.
Shen, H. (2014) On the direct strength and effective yield strength method design of medium and
high strength steel welded square section columns with slender plate elements, Steel and
Composite Structures, 17(4): 497-516.
Shen, H. (2015), Behavior of high-strength steel welded rectangular section beam–columns with
slender webs, Thin-Walled Structures, 88: 16-27.
Usami, T. and Fukumoto, Y. (1982) Local and overall buckling of welded box columns,
Structural Division, 108(3): 525-542.
Uy, B. (1998), “Local and post-local buckling of concrete filled steel welded box columns,
Constructional Steel Research, 47(1–3): 47–72.
Uy, B. (2000) Strength of concrete filled steel box columns incorporating local buckling,
Structural Engineering, 126(3): 341-352.
Yang, L., Zhao, M., Xu, D., Shang, F., Yuan, H., Wange, Y. and Zhang, Y. (2016) Flexural
buckling behavior of welded stainless steel box-section columns, Thin-Walled Structures,
: 185–197.