DESIGN OF A SINGLE-PHASE RADIAL FLUX PERMANENT MAGNET GENERATOR WITH VARIATION OF THE STATOR DIAMETER

Authors

  • Hari Prasetijo Department of Electrical Engineering, Faculty of Engineering, Jenderal Soedirman University, Purwokerto, Indonesia
  • Winasis Winasis Department of Electrical Engineering, Faculty of Engineering, Jenderal Soedirman University, Purwokerto, Indonesia
  • Priswanto Priswanto Department of Electrical Engineering, Faculty of Engineering, Jenderal Soedirman University, Purwokerto, Indonesia
  • Dadan Hermawan Department of Chemistry, Faculty of Sciences, Jenderal Soedirman University, Purwokerto, Indonesia

DOI:

https://doi.org/10.11113/jt.v81.12889

Keywords:

Permanent magnet generator, radial flux, flux density, voltage, power

Abstract

This study aims to observe the influence of the changing stator dimension on the air gap magnetic flux density (Bg) in the design of a single-phase radial flux permanent magnet generator (RFPMG). The changes in stator dimension were carried out by using three different wire diameters as stator wire, namely, AWG 14 (d = 1.63 mm), AWG 15 (d = 1.45 mm) and AWG 16 (d = 1.29 mm). The dimension of the width of the stator teeth (Wts) was fixed such that a larger stator wire diameter will require a larger stator outside diameter (Dso). By fixing the dimensions of the rotor, permanent magnet, air gap (lg) and stator inner diameter, the magnitude of the magnetic flux density in the air gap (Bg) can be determined. This flux density was used to calculate the phase back electromotive force (Eph). The terminal phase voltage (V∅) was determined after calculating the stator wire impedance (Z) with a constant current of 3.63 A. The study method was conducted by determining the design parameters, calculating the design variables, designing the generator dimensions using AutoCad and determining the magnetic flux density using FEMM simulation.  The results show that the magnetic flux density in the air gap and the phase back emf Eph slightly decrease with increasing stator dimension because of increasing reluctance. However, the voltage drop is more dominant when the stator coil wire diameter is smaller. Thus, a larger diameter of the stator wire would allow terminal phase voltage (V∅) to become slightly larger. With a stator wire diameter of 1.29, 1.45 and 1.63 mm, the impedance values of the stator wire (Z) were 9.52746, 9.23581 and 9.06421 Ω and the terminal phase voltages (V∅) were 220.73, 221.57 and 222.80 V, respectively. Increasing the power capacity (S) in the RFPMG design by increasing the diameter (d) of the stator wire will cause a significant increase in the percentage of the stator maximum current carrying capacity wire but the decrease in stator wire impedance is not significant. Thus, it will reduce the phase terminal voltage (V∅) from its nominal value.

References

Erinofiardi, Syaiful, M., Prayitno, A. 2015. Electric Power Generation from Low Head Simple Turbine for Remote Area Power Supply. Jurnal Teknologi. 74(5): 21-25.

Date, A., Akbarzadeh, A., Alam, F. 2012. Examining the Potential of Split Reaction Water Turbine for Ultra-Low Head Hydro Resources. Procedia Engineering. 49: 197-204.

Jin-Hyung Yoo, Chang-Seok Park, Tae-Uk Jung. Permanent Magnet Structure Optimization for Cogging Torque Reduction of Outer Rotor Type Radial Flux Permanent Magnet Generator. IEEE International Electric Machines and Drives Conference (IEMDC) 2017.

Prasetijo, H. 2013. Prototype Permanent Magnetic Generator Axial AC 3 Phase As Pico Hydro Power Generating Components. Proceedings of the National Seminar on Rural Resource Development and Local Wisdom III. Part IV. Unsoed. Purwokerto 2013. 26-37.

Kasim, dkk. 2011. Analysis of the Effect of Air Pass Flux Meeting on Permanent Magnet Generator Characteristics. Journal of Electricity and Renewable Energy. 10: 123-130.

Sharma Pawan, T. S. Bhatti, dan K. S. S. Ramakrishnan. 2011. Permanent-magnet Induction Generators. New Delhi: Indian Institute of Technology Delhi.

Gor, H., Kurt,E. 2015. Preliminary Studies of New Permanen Magnet Generator with the Axial and Radial Flux Morphology. International Journal of Hydrogen Energy. 41(17): 7005-7018.

Faiz, J., Valipour, Z., Kojouri, S. M. 2016. Design of a Radial Flux Permanent Magnet Wind Generator with Low Coercive Force Magnets. 2016 2nd International Conference on Intelligent Energy and Power Systems (IEPS). Kiev, Ukraine. IEEE Xplore. 28 July 2016.

Reljic, D., Corba, Z., Dumnic, B. 2010. Application of Permanen Magnet Synchronous Generator within Small-Scale Hydropower System. Journal on Processing and Energy in Agriculure.14(3): 149-152.

Zhang, X., Du, Q., Ma, C., Ma, S., Xu, J., Geng, H., Tian, G. 2016. Ne-Fe-B Permanen Magnet Generator and Voltage Stabilizing Control Technology for Vehicles. Advance in Mechanical Engineering. 8(9): 1-11.

Dutta, R., Rahman, F. 2005. Interior Permanen Magnet Generator: Generator of New Millenium. International Energy Journal. 6(1): 51-57.

Irasari, P. 2012. Simulation and Magnetic Analysis of Permanent Magnetic Permanent Flux Generator Generator Using Finite Element Method. Mechatronics, Electrical Power, and Vehicular Technology. 3: 23-30.

Kallaste, A., Vaimann, T., Belahcen, A. 2017. Influence of Magnet Material Selection on the Design of Slow-Speed Permanent Magnet Synchronous Generators for Wind Applications. Elektronika IR Elektrotechnika. 23(1): 31-38.

Herudin dan Wahyu Dwi Prasetyo. 2016. Synchronous Generator Build 1 Permanent Magnetic Phase Low Speed 750 RPM. Scientific Journal of Strum UNTIRTA. 11-15.

Ahmed, D., Ahmad, A. 2013. An Optimal Design of Coreless Direct-drive Axial Flux Permanent Magnet Generator for Wind Turbine. 6th Vacuum and Surface Sciences Conference of Asia and Australia (VASSCAA-6).

Prasetijo, H., Waluyo, S. 2015. Optimization of Air-gap Rotor-stator Width Without Nucleus Axial Magnet Permanent Low Phase 1 Phase using FEMM 4.2. Journal of National Electrical Engineering and Information Technology UGM. 4(4): 2015.

Downloads

Published

2019-06-25

Issue

Section

Science and Engineering

How to Cite

DESIGN OF A SINGLE-PHASE RADIAL FLUX PERMANENT MAGNET GENERATOR WITH VARIATION OF THE STATOR DIAMETER. (2019). Jurnal Teknologi (Sciences & Engineering), 81(4). https://doi.org/10.11113/jt.v81.12889