Abstract

Cancer and breast tissue have a very high electrical impedance ratio, so imaging based on impedance can produce high contrast. It is very useful for the early detection of breast cancer. Trans-admittance mammography (TAM) is a modality to detect breast cancer based on impedance. The weakness of TAM is that it can only produce a projection image so that the volume and ratio of cancer to breast tissue cannot be obtained at once. The ratio of anomaly and volume is very important to be determined properly because it is related to the stage and type of cancer. TAM shortcomings can be overcome if anomalous volume information is known precisely. The ultrasound reflection modality can produce information about an anomaly depth and volume correctly. Combining TAM and ultrasound reflection data is expected to provide promising results. The study was conducted to prove the hypothesis by creating a breast phantom composed of gelatin, agar, graphite, glycerol, and distilled water to represent the electrical and acoustic physical properties of cancer and breast tissue. The results showed that the TAM data was only able to produce information about transverse position accurately, while the depth was less accurate. Acoustic devices can produce transverse position information, depth, and volume precisely. The dual-modality of TAM and ultrasound reflection can produce information about the depth position, volume, and the ratio anomaly to reference conductivity accurately.

References

Ain, K., Kurniadi, D., Soeprijanto, Santoso, O. 2017. Dual Modality Electrical Impedance and Ultrasound Reflection Tomography to Improve Image Quality. Journal of Electrical Bioimpedance. 3: 3-10.

Arad, M., Adunsky, A. 2010. Diagnosis of Elderly Pneumonia Patients Using a Parametric Electrical Impedance Tomography System–A Preliminary Study. Int. J. Medical Engineering and Informatic. 2(4): 355-363.

Bera, T. K., and Nagaraju, J. 2014. Studying the Resistivity Imaging of Practical Phantoms with Common Ground Current Injection Technique in Electrical Impedance Tomography. Int. J. Communication Networks and Distributed System. 12(1): 47-68.

Bijwaard, H., Brenner, A., Dekkers, F., Dillen T. V., Land C. E, Boice J. D. 2010. Breast Cancer Risk from Different Mammography Screening Practices. Radiat Res. 174: 367-376.

Breast Cancer Facts & Figures. 2015-2016. The American Cancer Society, Atlanta. (https://www.cancer.org/research/cancer-facts-statistics/breast-cancer-facts-figures.html).

Cherepenin, V. A., Karpov, A. Y., Korjenevsky, A. V., Kornienko, V. N., Kultiasov, Y. S., Ochapkin, M. B., Trochanova, O. V., and Meister, J. D. 2002. Three-Dimensional EIT Imaging of Breast Tissues: System Design and Clinical Testing. IEEE Transactions on Medical Imaging. 21(6): 662-667.

Holder, D. S. 2005. Electrical Impedance Tomography, Methods History and Application. Institute of Physics Publishing, Bristol and Philadelpia.

Hope, T. A. and Iles, S. E. 2004. Technology Review: The Use of Electrical Impedance Scanning in the Detection of Breast Cancer. Breast Cancer Res. 6: 69-74.

Hu, G., and He, B. 2011. Magneto-acoustic Imaging of Electrical Conductivity of Biological Tissues at a Spatial Resolution Better than 2 mm. PLoS ONE. 6(8).

Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., and Forman, D. 2011. Global Cancer Statistics. CA Cancer Journal CLIN. 61(2): 69-90. DOI: 10.3322/caac.20107.

Jossinet, J. 1998. The Impedivity of Freshly Excised Human Breast Tissue. Physiol. Meas. 19: 61-75.

Kao. T. J, Saulnier, G. J., Xia, H., Tamma, C., Newell, J C. and Isaacson, D. 2007. A Compensated Radiolucent Electrode Array for Combined EIT and Mammography. Physiological Measurement. 28(7): S291-S299.

Kerner, T. E., Paulsen, K. D., Hartov, A., Soho, S. K., and Poplack, S. P. 2002. Electrical Impedance Spectroscopy of the Breast: Clinical Imaging Results in 26 Subjects. IEEE Transactions on Medical Imaging. 21(6): 638-645.

Keshtkar, A., Mesbahi, A., and Mehnati, P. 2008. The Effect of Bladder Volume Changes on the Measured Electrical Impedance of the Urothelium. Int. J. Biomedical Engineering and Technology. 1(3): 297-292.

Lee, C. H., D. Dershaw, D., Kopans, D., Evans, P., Monsees, B., Monticciolo, D., Brenner, R. J., Bassett, L., Berg, W., Feig, S., Hendrick, E., Mendelson, E., D’Orsi, C., Sickles, E., and Burhenne, L. W. 2010. Breast Cancer Screening with Imaging: Recommendations from the Society of Breast Imaging and the ACR on the Use of Mammography, Breast MRI, Breast Ultrasound, and Other Technologies for the Detection of Clinically Occult Breast Cancer. Journal American College of Radiology. 7(1): 18-27. DOI: 10.1016 / j.jacr.2009.09.022.

Lee, J. H., Kim, S. H., Kim, S., Seo, J. K., Zribi, H., Woo, E. J. 2007. New Anomaly Detection Algorithm Using Multi Frequency Trans-admittance Maps. 13th International Conference on Electrical Bio-impedance and the 8th Conference on Electrical Impedance Tomography, IFMBE Proceedings. 17: 392-395.

Oh, T. I., Lee, J., Seo, J. K., Kim, S. W., and Woo, E. J. 2007. Feasibility of Breast Cancer Lesion Detection Using a Multi-frequency Trans-admittance Scanner (TAS) with 10 Hz to 500 kHz Bandwidth. Physiol. Meas. 28: S71-S84, 71-84. Doi:10.1088/0967-3334/28/7/S06.

Omoleke, S. A. and Lawal, I. 2016. Cancer Care in Developing Countries: Does Early Detection Truly Save Lives. Journal of Women's Health Care. 5(2). DOI:10.4172/2167-0420.1000305.

Prasad, S. N.,Houserkova D, Campbell J. 2008. Breast Imaging using 3D Electrical Impedence Tomography. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 15(1): 151-154.

Sardanelli, F., Giuseppetti, G. M., Panizza, P., Bazzocchi, M., Fausto, A., Simonetti, G., Lattanzio, V., Maschio, A. D. 2004. Sensitivity of MRI Versus Mammography for Detectingfoci of Multifocal, Multicentric Breast Cancer in Fatty and Dense Breasts Using the Whole-breast Pathologic Examination as a Gold Standard. American Journal of Roentgenology. 183(4): 1149-1157.

Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., Smith, R. A., Warner, E., Yaffe, M., Andrews, K. S., Russell, C. A. 2007. American Cancer Society Guidelines for Breast Screening With MRI as an Adjunct to Mammography. CA: A Cancer Journal for Clinicians. 57(2): 75-89. DOI: 10.3322/canjclin.57.2.75.

Seo, J. K., Kwon, O., Ammari, H., and Woo, E. J. 2004. A Mathematical Model for Breast Cancer Lesion Estimation: Electrical Impedance Technique Using TS2000 Commercial System. IEEE Transactions on Biomedical Engineering. 51(11): 1898-1906.

Shao, W. and Adams, R. S. 2012. Multi-polarized Microwave Power Imaging Algorithm for Early Breast Cancer Detection. Progress in Electromagnetic Research. 23: 93-107.

Surowiec, A. J., Stuchly, S. S., Barr, J. R., and Swarup, A. 1998. Dielectric Properties of Breast Carcinoma and the Surrounding Tissues. IEEE Transactions on Biomedical Engineering. 35(4): 257-263.

Zhang, T., Lee, E., and Seo, J. K. 2014. Anomaly Depth Detection in Trans-admittance Mammography: A Formula Independent of Anomaly Size or Admittivity Contrast. Inverse Problems. 8: 1-22. DOI:10.1088/0266-5611/30/4/045003.

Zhao, M., Wi, H., Oh, T. I., Woo, E. J. 2013. Evaluation of Anomaly Detection Algorithm Using Trans-Admittance Mammography with 60×60 Electrode Array. Engineering in Medicine and Biology Society (EMBS). 35th Annual International Conference of the IEEE EMBS. 6433-6436.

Zou, Y. and Guo, Z. 2003. A Review of Electrical Impedance Technique for Breast Cancer Detection. Medical Engineering and Physics. 25: 79-90.

Downloads

Published

2020-05-22

Issue

Section

Science and Engineering

How to Cite

DUAL MODALITY TRAN-ADMITTANCE MAMMOGRAPHY AND ULTRASOUND REFLECTION TO IMPROVE ACCURACY OF BREAST CANCER DETECTION. (2020). Jurnal Teknologi (Sciences & Engineering), 82(4). https://doi.org/10.11113/jt.v82.14491