Meramal Aliran Udara dan Keselesaan di dalam Masjid Sultan Salahuddin Abdul Aziz Shah Menggunakan Simulasi Komputer
DOI:
https://doi.org/10.11113/jt.v69.1612Keywords:
Thermal comfort, air movement, air temperature, simulation, buildingAbstract
A study on ventilation system using a two dimensional turbulence k-e model with the assumption that the fluid is incompressible and non-isothermal is presented. The purpose of this study is to predict the distribution of air velocity and temperature in main hall Masjid Sultan Salahuddin Abdul Aziz Shah in Shah Alam. When the airflow and temperature distribution have been predicted by the computer software FLUENT, the comfort level can easily be determined. Nine cases have been conducted to examine the effects of input air velocity, air velocity from the fan heli and fan air flow direction to the percentage of consumer dissatisfaction. Mixing characteristics of comfort have been analyzed under different air supply velocities, temperatures and fan velocities. The fan velocity directions involved two conditions which are the upwards and downwards directions. The results from the research in the form of air velocity and temperature distributions are important in determining the comfort level which is unsuitable for the user. It was found that cases of 3,4, 5, 6 and 7 show the effect of a very good comfort with the percentage of PPD between 10% to 20%. The location of heli fans also affects the impression of comfort in the main hall. The comfort level of this area can be improved by modifying the position and increasing the number of fans in the hall.
References
H. Xue dan C. Shu. 1999. Mixing Characteristics in a Ventilated Room with Non-Isothermal Ceiling Air Supply. Building and Environment. 34: 254–251.
M. Nady A. Said, Jianshun S. Zhang, Shaw, S. Y dan Christianson, L. L. 1995. Computation of Room Air Distribution. ASHRAE Tranc. 1065–1077.
Shuzo Murakami, Shinsuke Kato, Kiyota Deguchi, Takeo Takahashi, Isao Makimura dan Yasushi Kondo. 1995. Natural Ventilation of a Large-Scale Wholesale Market Building. ASHRAE Tranc. 44–54.
Heiselberg, P. 1997. Room Air and Contaminant Distribution in Mixing Ventilation. ASHRAE Tranc. 332–339.
A. Yaghoubi, Mahmood, Knappmiller, K. D dan Kirkpatrick, A. T. 1995. Three-Dimensional Numerical Simulation of Air Contaimination Disperal in a Room. ASHRAE Tranc. 1031–1040.
Schaub, E. G, Kelso, R. M dan Baker, A. J. 1995. Comparing The Continuity-Constraint Algorithm Results with a Full-Scale Laboratory Test. ASHRAE Tranc. 1041–1053.
Baker, A. J, Williams, P. T daan Kelso, R. M. 1992. Numerical Calculation of Room Air Motion-Part 1: Math, Physics and CFD Modeling. ASHRAE Tranc. 514–530.
Baker, A. J, Williams, P. T daan Kelso, R. M. 1992. Numerical Calculation of Room Air Motion-Part 2: The Continuity Constraint Finite Element Method for Three-Dimensional Incompressible Thermal Flow. ASHRAE Tranc. 531–548.
Baker, A. J, Williams, P. T daan Kelso, R. M. 1992. Numerical Calculation of Room Air Motion-Part 3: Three-Dimensional CFD Simulation of a Full-Scale Room Air Experiment. ASHRAE Tranc. 549–564.
Abwi, H. B. 1995. Ventilation of Building. Second Edition. F & F Spoon Press,
Sarip. S. 2002. Meramal Aliran Udara dan Keselesaan di dalam Ruang Besar. Master Thesis. Universiti Teknologi Malaysia.
Downloads
Published
Issue
Section
License
Copyright of articles that appear in Jurnal Teknologi belongs exclusively to Penerbit Universiti Teknologi Malaysia (Penerbit UTM Press). This copyright covers the rights to reproduce the article, including reprints, electronic reproductions, or any other reproductions of similar nature.