Seismic Behaviour Of Base Isolation System Using Lead Rubber Bearing

Authors

  • A. V. Hadian Department of Civil and Structural Engineering, Faculty of Engineering and Built Environment, University Kebangsaan Malaysia, 43600 UKM, Bangi, Selangor, Malaysia
  • A. A. Mutalib Department of Civil and Structural Engineering, Faculty of Engineering and Built Environment, University Kebangsaan Malaysia, 43600 UKM, Bangi, Selangor, Malaysia
  • S. Baharom Department of Civil and Structural Engineering, Faculty of Engineering and Built Environment, University Kebangsaan Malaysia, 43600 UKM, Bangi, Selangor, Malaysia

DOI:

https://doi.org/10.11113/jt.v65.2195

Keywords:

LRB system, seismic, fixed base system, base isolation system, response spectrum analysis, time history analysis

Abstract

Nowadays the main cause of damage of reinforced concrete frames in the countries which are located on the seismic line area is earthquake even though they are designed due to the enactment of seismic codes. To provide a solution to these problems, Lead Rubber Bearing (LRB) system has been utilized in the construction of the buildings. Hence, the objective of this study is to determine the best configuration of the LRB in the structure by calculating the response of the structure, roof level acceleration and inter-story displacement based on the ground motion records. The study consists of determining the structure, calculating the weight of structure, modelling the LRB in the structure and obtaining the output from the dynamic analyses. The comparison of the inter-story displacement, drifts frames and top level acceleration response of the LRB system with the Fixed Base System (FBS) using spectrum and time history analysis shows that the base shear reduces by 65–75% in response spectrum analysis, while in time history analysis base shear reduces by 75–85%. The proposed method is based on the LRB system that reduces the response of the structure because of high damping and stiffness used in the Base Isolation System (BIS) and capable to be used for super structure located in the seismic line area. This system would help in reducing the cost in the long time and increase the safety of the structure. 

References

Deb, S. K. 2004. Seismic Base Isolation–An overview. Current Science. 87(10): 1426–1430.

International Building Code, International Code Council. 2009. IBC 2009.

Islam,ABMS, Jameel, M. &Jumaat, M. Z. 2011a. Seismic Isolation in Buildings to be a Practical Reality. Behavior of Structure and Installation Technique. 3(4): 97–117.

Islam, ABMS, Jameel, M. & Jumaat, M. Z. 2011b. Study on Optimal Isolation System and Dynamic Structural Responses in Multi-Story Buildings. 6(9): 2219–2228.

Islam, ABMS., Jameel, M., Ahmad, S. I. & Jumaat, M. Z. 2011c. Study on Corollary of Seismic Base Isolation System on Buildings with Soft Story. 6(11): 2654–2661.

Islam, ABMS, Jameel, M., Ahmad, S. I., Salman, F. A. & Jumaat, M. Z. 2011e. Engendering Earthquake Response Spectra for Dhaka Region Usable in Dynamic Analysis of Structures. 6(16): 3519–3530.

Islam, ABMS, Jameel, M., Rahman, M. A. & Jumaat, M. Z. 2011d. Earthquake Time History for Dhaka, Bangladesh as Competent Seismic Record. 6(13): 2514–2520.

Kelly, J. M. & Naeim, F. 1999. Design of Seismic Isolated Structures: From Theory to Practice, Inc. New York: John Wiley and sons.

Kelly, T. E. 2001. Base Isolation of Structures: Design guidelines. Auckland: Holmes Consulting Group Ltd. Available from www.holmesgroup.com.

Lu, L. Y. & Lin, G. L. 2008. Predictive Control of Smart Isolation System for Precision Equipment Subjected to Near-fault Earthquakes. 30: 3045–3064.

Downloads

Published

2013-10-15

Issue

Section

Science and Engineering

How to Cite

Seismic Behaviour Of Base Isolation System Using Lead Rubber Bearing. (2013). Jurnal Teknologi, 65(2). https://doi.org/10.11113/jt.v65.2195