The Benefits and Limitations of Methods Development in Solid Phase Extraction: Mini Review

Authors

  • Norfahana Abd-Talib Institute Bioproducts Development, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Siti Hamidah Mohd-Setapar Centre of Lipid Engineering and Applied Research, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Aidee Kamal Khamis Institute Bioproducts Development, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia

DOI:

https://doi.org/10.11113/jt.v69.3177

Keywords:

Solid phase extraction, benefits, limitations

Abstract

Over recent years, there has been an explosive growth of sample preparation techniques. Sample preparation is in most cases meant to be the isolation online or offline concentration of some components of interest or target analytes. Solid phase extraction (SPE) is a very popular technique nowadays in sample preparation. The principal is quite similar with liquid- liquid extraction (LLE) which involves partition of solutes between two phases. But, there are some differences between them and some benefits and limitations of difference types of SPE technique like presented in this paper.

References

Chen, Y., G. Zhenpeng, W. Xianyu and Q. Changgui. 2008. Sample preparation. Journal of Chromatography. 1184(1–2): 191–219.

Flores, É. M. M., B. Juliano., M. Marcia and K. Gunter. 2007. Sample Preparation Techniques Based on Combustion Reactions in Closed Vessels–A Brief Overview and Recent Applications. Spectrochimica Acta Part B: Atomic Spectroscopy. 62(9): 1051–1064.

Goodwin, R. J. A. 2012. Sample Preparation for Mass Spectrometry Imaging: Small Mistakes Can Lead to Big Consequences. Journal of Proteomics. 5(16): 4893–4911.

Nóbrega, J. A., S. Mirian, d. Rafael, C. Selange, B. Ramon and T. Mark. 2006. Sample Preparation in Alkaline Media. Spectrochimica Acta Part B: Atomic Spectroscopy. 61(5): 465–495.

Majors, P. D., J. S. McLean and J. C. M. Scholten. 2008. NMR Bioreactor Development for Live In-situ Microbial Functional Analysis. Journal of Magnetic Resonance. 192(1): 159–166.

Hu, G., J. S. H. Lee and D. Li. 2006. A Microfluidic Fluorous Solid-phase Extraction Chip for Purification of Amino Acids. Journal of Colloid and Interface Science. 301(2): 697–702.

Nilsson, U. J., E. J. L. Fournier and O. Hindsgaul. 1998. Solid-phase Extraction on C18 Silica as a Purification Strategy in the Solution Synthesis of a 1-Thio-Β-D-Galactopyranoside Library. Bioorganic & Medicinal Chemistry. 6(9): 1563–1575.

Tarn, M. D., P. Giancarlo, D. Francesco, W. Paul, S. Piero and A. P. Nicole. 2013. Purification of 2-[18F]fluoro-2-deoxy-d-glucose by on-Chip Solid-phase Extraction. Journal of Chromatography. 1280: 117–121.

Bagheri, H., A. Mohammadi and A. Salemi. 2004. On-line Trace Enrichment of Phenolic Compounds from Water Using a Pyrrole-Based Polymer as the Solid-phase Extraction Sorbent Coupled with High-performance Liquid Chromatography. Analytica Chimica Acta, 513(2): 445–449.

Crespín, M. A., E. Ballesteros, M. Gallengo, M. Valcarcel. 1997. Trace Enrichment of Phenols by On-line Solid-phase Extraction and Gas Chromatographic Determination. Journal of Chromatography. 757(1–2): 165–172.

Fischer, J., M. T. Kelly, M. R. Smyth and P. Jandera. 1993. Determination of Ivermectin in Bovine Plasma by Column-switching LC Using On-line Solid-phase Extraction and Trace Enrichment. Journal of Pharmaceutical and Biomedical Analysis. 11(3): 217–223.

Gilar, M., A. Belenky and B. H. Wang. 2001. High-throughput Biopolymer Desalting by Solid-phase Extraction Prior to Mass Spectrometric Analysis. Journal of Chromatography. 921(1): 3–13.

Palmblad, M. and J. S. Vogel. 2005. Quantitation of Binding, Recovery and Desalting Efficiency of Peptides and Proteins in Solid Phase Extraction Micropipette Tips. Journal of Chromatography. 814(2): 309–313.

Watkins, L. K., P. V. Bondarenko, D. C. Barbacci, S. Song, S. L. Cockrill, D. H. Russell and R. D. Macfarlane. 1999. Fast C18 Solid-Phase Desalting/Delipidation of the Human Serum Apolipoproteins for Matrix-assisted Laser Desorption Ionization and Electrospray Ionization Mass Spectrometric Analysis. Journal of Chromatography. 840(2): 183–193.

Mulugeta, M., G. Wibetoe, C. J. Engelsen and W. Lund. 2009. Fractionation Analysis of Oxyanion-forming Metals and Metalloids in Leachates of Cement-based Materials Using Ion Exchange Solid Phase Extraction. Talanta. 78(3): 736–742.

Zelles, L. and Q. Y. Bai. 1993. Fractionation of Fatty Acids Derived From Soil Lipids by Solid Phase Extraction and Their Quantitative Analysis by GC-MS. Soil Biology and Biochemistry. 25(4): 495–507.

Poole, C. F., A. D. Gunatilleka and R. Sethuraman. 2000. Contributions of Theory to Method Development in Solid-phase Extraction. Journal of Chromatography. 885(1–2): 17–39.

Lindenblatt, H., K. Edda., H. Petra., G. Euphrisyne and K. Karl-Artur. 1998. Quantitation of Psilocin in Human Plasma by High-performance Liquid Chromatography and Electrochemical Detection: Comparison of Liquid–Liquid Extraction with Automated On-line Solid-phase Extraction. Journal of Chromatography B: Biomedical Sciences and Applications. 709(2): 255–263.

Hernanz, D., V. Gallo, A. F. Recamales, A. J. Melendez-Martinez and F. J. Heredia. 2008. Comparison of the Effectiveness of Solid-phase and Ultrasound-mediated Liquid–liquid Extractions to Determine the Volatile Compounds of Wine. Talanta. 76(4): 929–935.

Xie, W., J. Pawlisyn, W. M. Mulle and B. K. Matuszewski. 2007. Comparison of Solid-phase Microextraction and Liquid–liquid Extraction in 96-Well Format for the Determination of a Drug Compound in Human Plasma by Liquid Chromatography with Tandem Mass Spectrometric Detection. Journal of Pharmaceutical and Biomedical Analysis. 45(4): 599–608.

Poole, C. F., S. K. Poole, D. S. Seibert and C. M. Chapman. 1997. Determination of Kinetic and Retention Properties of Cartridge and Disk Devices for Solid-phase Extraction. Journal of Chromatography B: Biomedical Sciences and Applications. 689(1): 245–259.

Mayer, M. L. and C. F. Poole. 1994. Identification of the Procedural Steps that Affect Recovery of Semi-volatile Compounds by Solid-Phase Extraction Using Cartridge and Particle-loaded Membrane (Disk) devices. Analytica Chimica Acta. 294(2): 113–126.

Horne, T. and S. Holt-Larkin. 1997. Solid-phase Extraction of Phospholipids from Hemoglobin Solutions Using Empore Styrene–Divinylbenzene Disks. Journal of Chromatography B: Biomedical Sciences and Applications. 695(2): 259–267.

Thompson, T. S. and B. D. Miller. 1998. Use of Solid Phase Extraction Disks for the GC-MS Analysis of Acidic and Neutral Herbicides in Drinking Water. Chemosphere. 36(14): 2867–2878.

Thurman, E. M. and K. Snavely. 2000. Advances in Solid-phase Extraction Disks for Environmental Chemistry. TrAC Trends in Analytical Chemistry. 19(1): 18–26.

Nema, T., E. C. Y. Chan and P. C. Ho. 2010. Application of Silica-based Monolith as Solid Phase Extraction Cartridge for Extracting Polar Compounds from Urine. Talanta. 82(2): 488–494.

Vuckovic, D. 2013. High-throughput Solid-phase Microextraction in Multi-well-Plate Format. TrAC Trends in Analytical Chemistry. 45: 136–153.

Downloads

Published

2014-06-25

How to Cite

The Benefits and Limitations of Methods Development in Solid Phase Extraction: Mini Review. (2014). Jurnal Teknologi, 69(4). https://doi.org/10.11113/jt.v69.3177