Improving Performance of Water Treatment on Oxidation Ditch Using Modification of Reactor Hydrodynamic

Authors

  • Rositayanti Hadisoebroto Faculty of Civil and Environmental Technology, Bandung Institute of Technology, Bandung, Indonesia
  • Idris Maxdoni Kamil Faculty of Civil and Environmental Technology, Bandung Institute of Technology, Bandung, Indonesia
  • Suprihanto Notodarmojo Faculty of Civil and Environmental Technology, Bandung Institute of Technology, Bandung, Indonesia
  • Yazid Bindar Faculty of Industrial Technology, Bandung Institute of Technology, Bandung, Indonesia

DOI:

https://doi.org/10.11113/jt.v69.3249

Keywords:

Hydraulic aspect, computer simulation, wastewater treatment plant

Abstract

Urban wastewater treatment in Indonesia is limited, due to its high investment cost. To date, there are only 11 big cities that have centralized domestic wastewater treatment plant, such as in Jakarta, Tangerang, Bandung, Medan, Yogyakarta and Surakarta. There is also city sludge faecal treatment plant, like in Surabaya, Jakarta, Yogyakarta and Semarang. All the treatment process in these treatment plants is based on biological process, which are oxidation ditch (Tangerang and Surabaya), stabilization pond (Bandung) and extended aeration (Jakarta and Yogyakarta). Mostly, the biological treatment on the plants are malfunctioning, some of them because of operational capacity which cannot fulfill the design capacity. Yet, the effort of optimization only focuses on biological process aspect, while the hydraulic and physical aspects have a great influence to treatment performance. Research on modification of hydraulic aspect, both experimentally and by using computer simulation to improve treatment performance is needed.

References

US-EPA. 2000. Waste Water Treatment Manuals Treatment Systems For Small Communities, Business, Leisure Centres and Hotels.

Yongzhen, Peng, Hongxun, Hou, Shuying, Wang, Youwei, Cui, Yuan, Zhiguo. 2008. Nitrogen and Phosphorus Removal ini Pilot-scale Anaerobic-Anoxic Oxidation Ditch System. Journal of Environmental Science. 20: 398–403.

Public Works Ministry. 2007. Design of Centralized Wastewater Management, Indonesia.

Yetilmezsoy, Kaan. 2010. Modeling Studies for the Determination of Completely Mixed Activated Sludge Reactor Volume: Steady-state, Empirical and Ann Applications. Neural Network World. 5: 559–589.

IAEA (International Atomic Energy Agency). 2011. Radiotracer Applications in Wastewater Treatment Plants, Training Course, Vienna.

Fall, C. Loaiza-Navia, J. L. 2007. Design of a Tracer Test Experience and Dynamic Calibration of the Hydraulic Model for a Full-scale Wastewater Treatment Plant by Use of AQUASIM. Water Environment Research. 79(8): 893.

Sadiq Al-Baghdadi, Maher A.R, Abdolhamid, Hashim R., Elgarni, Mohamed, M. 2009. CFD Modeling of Contaminant Transport In Soils Including The Effect of Chemical Reactions. Ovidius University Annals of Chemistry. 20(1): 40–43.

Andrei, Luminita Constanta. 2011. Numerical Simulation Of Pollutants Dispersion Processes In Danube River, Ecoterra. 28.

Wols, Bas. 2010. CFD in Drinking Water, Dissertasion TU Delft.

Wang, Xu, Ding, Jie, Guo, Wan-Qian, Ren, Nan-Qi. 2010. A Hydrodynamics–Reaction Kinetics Coupled Model for Evaluating Bioreactorsderived From CFD Simulation. Bioresource Technology. 101: 9749–9757.

Kardono. 2006. Water Resource Management in Indonesia, Condition and Its Environmental Technology, BPPT, Indonesia .

Fitria, Diana. 2011. Wastewater Treatment Plant Tanah Tinggi Tangerang, Work Practice Report, Environmental Engineering Dept, Trisakti University.

Mendez-Romero, D. C., Lopez-Lopez, A., Vallejo-Rodriguez, E. Leon-Becerril. 2011. Hydrodynamic and Kinetic Assessment of an Anaerobic Fixed-Bed Reactor for Slaughterhouse Wastewater Treatment. Chemical Engineering and Processing. 50: 273–280.

Makinia, Jacek and Wells, Scott A. 2000. A General Model of The Activated Sludge Reactor With Dispersive Flow à I. Model Development And Parameter Estimation. Water Research. 34(16): 3987–3996.

Potier, Olivier, Leclerc, Jean-Pierre, Pons, Marie-Noe¨lle. 2005. Influence of Geometrical and Operational Parameters on the Axial Dispersion in an Aerated Channel Reactor. Water Research. 39: 4454–4462.

Le Moullec, Y., Gentric, C., Potier, O., Leclerc, J. P. 2007. CFD Simulation of the Hydrodynamics and Reactions in an Activated Sludge Channel Reactor of Wastewater Treatment.

Le Moullec, Yann, Potier, Olivier, Gentric, Caroline, Leclerc, Jean Pierre. 2008. Flow Field And Residence Time Distribution Simulation Of A Cross-Flow Gas–Liquid Wastewater Treatment Reactor Using CFD, Chemical Engineering Science. 63: 2436–2449.

Fan, Long, Xu, Nong, Wang, Zhiqiang, Shi, Hanchangi. 2010. PDA Experiments and CFD Simulation of a Lab-Scale Oxidation Ditch With Surface Aerators. Chemical Engineering Research and Design. 8: 23–33

Budianto, Hery. 2008. Developing Process Kinetics Model and Hydrodynamics on Dissolved Air Floatation Unit, and Improving Micro Bubble Lift Concept, Dissertation Bandung Institute of Technology.

Huang, Weidong, Wu, Chun du, Xiao, Bingjia, Xia, Weidong. 2005. Computational Fluid Dynamic Approach for Biological System Modeling.

Sah, Leena, Rousseau, Diederik P. L., Hooijmans, Christine M. 2012. Numerical Modelling of Waste Stabilization Ponds: Where Do We Stand? Water Air Soil Pollution.

Liu, Yanchen, Hanchang Shi, Zhiqiang Wang, Long Fan, Huiming Shi. 2013. Approach to Enhancing Nitrogen Removal Performance with Fluctuation of Influent in an Oxidation Ditch System. Chemical Engineering Journal. 219: 520–526.

Downloads

Published

2014-07-08

How to Cite

Improving Performance of Water Treatment on Oxidation Ditch Using Modification of Reactor Hydrodynamic. (2014). Jurnal Teknologi (Sciences & Engineering), 69(6). https://doi.org/10.11113/jt.v69.3249