Hardware Development of Electrical Capacitance Tomography (ECT) System with Capacitance Sensor for Liquid Measurements

Authors

  • Chan Kok Seong Process Tomography and Instrumentation Engineering Research Group (PROTOM-i), Infocomm Research Alliance, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Jaysuman Pusppanathan Process Tomography and Instrumentation Engineering Research Group (PROTOM-i), Infocomm Research Alliance, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Ruzairi Abdul Rahim Process Tomography and Instrumentation Engineering Research Group (PROTOM-i), Infocomm Research Alliance, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Goh Chiew Loon Process Tomography and Instrumentation Engineering Research Group (PROTOM-i), Infocomm Research Alliance, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Yvette Shaan-Li Susiapan Process Tomography and Instrumentation Engineering Research Group (PROTOM-i), Infocomm Research Alliance, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Fatin Aliah Phang Process Tomography and Instrumentation Engineering Research Group (PROTOM-i), Infocomm Research Alliance, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Mohd Hafiz Fazalul Rahiman Tomography Imaging Research Group, School of Mechatronic Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia

DOI:

https://doi.org/10.11113/jt.v73.4399

Keywords:

Ultrasonic Transducer, tomography, ADC, multi-level pulser, operational amplifier

Abstract

Electrical capacitance tomography system is useful for obtaining information about the spatial distribution of a mixture of dielectric materials inside a vessel. This research aims to obtain real-time monitoring on the composition for liquid mixture in conveying pipeline. ECT is a non-invasive, non-intrusive and non-destructive technique that can measure the flow level inside a pipeline. In order to increase the image resolution and accuracy of current tomography research, a study on 16 electrodes sensor ECT system has been developed. The developed system has the flexibility to be assembled and moved from a pipeline to another. The intelligent on-board flexibility and mobility sensor technique is a new technique for ECT system. The system can be assembled in different diameter sizes of pipeline, and numbers of electrodes sensor can be reduced accordingly depending on the pipeline sizes without the need to redesign the electrodes sensor. The new design is equipped with high speed data processing rate data acquisition system and high speed data reconstruction. A microcontroller that support full-speed USB data transfer rate has been designed as the centralization control unit. In order to improve data result, iterative algorithm has been implemented in this system in order to obtain a precise image of the flow in the pipeline. As a result, the ECT system is able to reconstruct various multiphase flow images. 

References

Malcolm Byars. 2001. Developments in Electrical Capacitance Tomography. PTL Application Notes.

Yang,W. Q., Spink, D. M., Gamio, J. C. and Beck, M. S. 1997. Sensitivity Distributions of Capacitance Tomography Sensors with Parallel Field Excitation. Meas. Sci. Technol. 8: 562–569.

Qussai Marashdeh,,Warsito Warsito,, Liang-Shih Fan, and Fernando L. Teixeira. A Multimodal Tomography System Based on ECT Sensors. IEEE Sensors Journal. 7(3): 426–433.

Tong Zhaoa, Masahiro Takeia, Kenta Masakia, Ryoji Ogiso, Koji Nakao, Akira Uchiura. 2007. Sensor Design and Image Accuracy for Application of Capacitance CT to the Petroleum Refinery Process. Flow Measurement and Instrumentation Journal. 18: 268–276.

A. Martínez Olmos, M. A. Carvajal, D. P. Morales, A. García, A. J. Palma. 2008. Development of an Electrical Capacitance Tomography System Using Four Rotating Electrodes. Sensors and Actuators A. 148 366–375.

Yang, W. Q., Spink, D. M., York, T. A. and McCann, H. 1999. An Image Reconstruction Algorithm Based on Landweber’s Iteration Method for Electrical Capacitance Tomography. Meas. Sci. Technol. 10: 1065–1069.

Xie, C. G., Huang, S. M., Hoyle, B. S., Lenn, C., Snowden, D., and Beck, M. S. 1992. Electrical Capacitance Tomography for Flow Imaging: System Model for Development of Image Reconstruction Algorithms and Design of Primary Sensors. IEE Proceedings-G. 139.

Tan Chee Wei. 2003. Measurement of Two-Phase Imaging (Water/Gas Bubbles) By Using Electrical Capacitance Tomography (ECT). Universiti Teknologi Malaysia: B.Sc. Thesis.

Javad Frounchi, Ali-Reza Bazzazi, Khabat Ebnabbasi and Kaveh Hosseini. 2003. High Speed Capacitance Measuring System for Process Tomography. 3rd World Congress on Industrial Process Tomography, Banff, Canada.

Philip Williams and Trevor York. 1999. Evaluation of Integrated Electrodes for Electrical Capacitance Tomography. 1st World Congress on Industrial Process Tomography, Buxton, Greater Manchester, April 14–17, 1999.

Tee, Z. C., Abdul Rahim, R., Chan, K. S., Electrical Capacitance Tomography Using Universal Serial Bus Technology, 3rd International Symposium on Process Tomography, Lodz, Poland 9–10 September 2004.

Yang Daoye, Zhou Bin, Xu Chuanlong, Tang Guanghua, Wang Shimin. 2009. Effect of Pipeline Thickness on Electrical Capacitance Tomography. Journal of Physics: Conference Series. 147.

J. Pusppanathan, et al. 2013. Study on Single Plane Ultrasonic and Electrical Capacitance Sensor for Process Tomography System. Sensors & Transducers. 150(3): 40–45.

M. J. Pusppanathan, F. R. Yunus, N. M. Nor Ayob, R. Abdul Rahim, F. A. Phang, H. Abdul Rahim, P.L Leow, K. H. Abas. September 2013. A Novel Electrical Capacitance Sensor Design For Dual Modality Tomography Multiphase Measurement. Jurnal Teknologi (Special Edition) (ISSN 2180-3722). 64(5): 45–47. doi 10.11113/jt.v64.2130.

Shahrulnizahani Mohammad Din, Aizat Azmi, Chee Pei Song, Ruzairi Abdul Rahim, Leow Pei Ling. July 2014. Electric Potential of Various 4-electrode Segmentation Excitation for Electrical Capacitance Tomography System. Jurnal Teknologi-Special Issue on Advanced Measurement and Sensor. 69(8): 35–38. eISSN 2180-3722.

Downloads

Published

2015-04-13

How to Cite

Hardware Development of Electrical Capacitance Tomography (ECT) System with Capacitance Sensor for Liquid Measurements. (2015). Jurnal Teknologi (Sciences & Engineering), 73(6). https://doi.org/10.11113/jt.v73.4399