CROSS VENTILATION ANALYSIS ON THE EFFECT OF SETBACK DISTANCE OF A TERRACED HOUSE USING PIV
DOI:
https://doi.org/10.11113/jt.v76.5545Keywords:
Cross ventilation, terraced house, setback distance, PIV, flow structureAbstract
Urban development has become very alarming with the rise of population especially in regions with weak wind such as countries in the tropics like Malaysia. The highly dense structures make it difficult to provide effective ventilation from heat, pollutions, dusts and even bacteria. With time, it will caused the urban area to become ‘sick’. Due to this, building arrangement plays an important part in predicting airflow structure and the effectiveness of ventilation from the developed airflow. Through this study, the effects of the setback distance arrangement, d, on the cross ventilation of two cascading terraced houses were analyzed. Based on the flow structure, the possibility of the negative effects from the upstream house carried in to the downstream house was also observed. The study was conducted experimentally using Particle Image Velocimetry (PIV) with the aid of INSIGHT 4G for post-processing analysis. It was found that the most ideal setback distance was d = 0.5H even though a higher H/W threshold ratio of the street canyon allowed the transition of wake interference flow to isolated roughness flow. Apart from that, the provided setback distance, d, can give sufficient ventilation on the downstream building.
References
Massey, J. and Massey, M. 1990. Finding Out About: The Urban Environment. London: Franklin Watts.
World Bank Group. 2015. East Asia's Changing Urban Landscape: Measuring a Decade of Spatial Growth. Washington, DC: World Bank. © World Bank. Information on https://openknowledge.worldbank.org/handle/10986/21159 License: CC BY 3.0 IGO.
Chung, L. P., Haji Ahmad, M. H., Ossen, D. R., and Hamid, M. 2014. Application of CFD Prediction of Indoor Building Thermal Performance as an Effective Pre-Design Tool towards Sustainability. World Applied Science Journal 30 (Innovation Challenges in Multidisciplinary Research & Practice. 269-279.
Kuala Lumpur Structure Plan 2020, Kuala Lumpur City Hall, Malaysia.
Bujang, A. A., Zarin, H. A., and Jumadi, N. 2010. The Relationship between Demographic Factors and Housing Affordability. Malaysian Journal of Real Estate. 5: 49-58.
Lim, Y. W. 2013. Indoor Environmental Comfort in Malaysian Urban Housing. American Journal of Environmental Science. 9(5): 431-438.
Baharum, M. A., Surat, M., Tawil, N. M. and Che-Ani, A. I. 2014. Modern Housing Tranquility in Malaysia from the Aspect of Thermal Comfort for Humid Hot Climate Zone. E3S Web Conference. 3: 01008.
Abd. Wahab, I., and Ismail, L. H. 2011. Natural Ventilation Approach in Designing Urban Tropical House. The International Conference on Civil and Environmental Engineering Sustainability (IConCEES 2011). Johor Bahru, Malaysia. 3-5 April 2012. 2538.
Tenth Malaysian Plan, Malaysian Government, Malaysia.
Jiang, Y., Alexander, D., Jenkins, H., Arthur, R. and Chen, Q. 2003. Natural Ventilation in Buildings: Measurement in a Wind Tunnel and Numerical Simulation with Large Eddy Simulation. Journal of Wind Engineering and Industrial Aerodynamics. 91: 331-53.
Ramponi, R. and Blocken, B. 2012. CFD Simulation of Cross-Ventilation Flow for Different Isolated Building Configurations: Validation with Wind Tunnel Measurements and Analysis of Physical and Numerical Diffusion Effect. Journal of Wind Engineering and Industrial Aerodynamics. 104-106: 408-418.
Kasim, N. F. M., Zaki, S. A., Hagishima, A., Ali, M. S. M., Shirakashi, Arai, M., N., Razak, A. A. 2014. CFD Study of Cross Ventilation Performance of Different Buildings Layout. 2nd Asia Conference of International Building Performance Simulation Association.
Oke, T.R. 1988. Street Design and Urban Canopy Layer Climate. Energy and Building. 11: 103-113.
Kubota, T. and Ahmad, S. 2006. Wind Environment Evaluation in Neighborhood Residential Areas in Malaysia: A Case Study of Johor Bahru Metropolitan City. Journal of Asian Architecture and Building Engineering. 5: 199-206.
Mohamad, M.F., Hagishima, A., Tanimoto, J., Ikegaya, N. and Omar, A. R. 2013. Wind-Induced Natural Ventilation in Typical Single-storey Terraced Houses in Malaysia. 13th Conference of International Building Performance Simulation Association. Chambery, France.
Mohamad, M. F., Hagishima, A., Tanimoto, J., Ikegaya, N. and Omar, A. R. 2014. On the Effect of Various Design Factors on Wind-Induced Natural Ventilation of Residential Buildings in Malaysia. 2nd Asia Conference of International Building Performance Simulation Association. Nagoya, Japan. December 2014.
Tuan, L., Abd Razak, A., Zaki, S. A., Mohammad, A. F., and Hassan, M. K. 2014. Large Eddy Simulation of Natural Ventilation for Idealized Terrace Houses Due to the Effect of Setback Distance. 7th International Conference on Cooling & Heating Technology. Subang, Malaysia. 4th-6th November 2014.
Downloads
Published
Issue
Section
License
Copyright of articles that appear in Jurnal Teknologi belongs exclusively to Penerbit Universiti Teknologi Malaysia (Penerbit UTM Press). This copyright covers the rights to reproduce the article, including reprints, electronic reproductions, or any other reproductions of similar nature.