THE EFFECT OF LIQUID SUCTION HEAT EXCHANGER SUB-COOLER ON PERFORMANCE OF A FREEZER USING R404A AS WORKING FLUID

Authors

  • Muhammad Nuriyadi Department of Refrigeration and Air Conditioning, Politeknik Negeri Bandung Gegerkalong Hilir Ciwaruga Bandung 40012, Indonesia
  • Sumeru Sumeru Department of Refrigeration and Air Conditioning, Politeknik Negeri Bandung Gegerkalong Hilir Ciwaruga Bandung 40012, Indonesia
  • Henry Nasution Automotive Development Centre, Faculty of Mechanical Engineering University Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia

DOI:

https://doi.org/10.11113/jt.v76.5914

Keywords:

LSHX, Freezer, R404A, cooling capacity, EER.

Abstract

This study presents the effect of liquid-suction heat exchangers (LSHX) sub-cooler in a freezer. The LSHX sub-cooler is a method to increase the cooling capacity of the evaporator by lowering temperature at the condenser outlet. The decrease in temperature of the condenser outlet will cause a decrease in the quality refrigerant entering the evaporator. The lower the quality of the refrigerant entering the evaporator, the higher the cooling capacity produced by the evaporator. The LSHX sub-cooler utilizes a heat exchanger to transfer heat from the outlet of the condenser (liquid line) to the suction of the compressor. In the present study, three different LSHX sub-coolers in the freezer with cabin temperature settings of 0, -10 and -20oC were investigated. The results showed that the lowest and the highest of effectiveness of the heat exchanger were 0.28 and 0.58, respectively. The experimental results also showed that EER reduction is occurred at the cabin temperature setting of 0oC and -10oC, whereas the EER improvements were always occurred at the cabin temperature settings of -20oC.

References

Qureshi, B. A. and Zubair, S. M. 2012. The Effect Of Refrigerant Combination On Performance Of A Vapor Compression Refrigeration System With Dedicated Mechanical Sub-Cooling. Int. J. Refrig. 35: 47-57.

Qureshi, B. A. and Zubair, S. M. 2012. The Impact Of Fouling On Performance Of A Vapor Compression Refrigeration System With Integrated Mechanical Sub-Cooling System. Appl. Energy. 92: 750-762.

Domanski, P. A., Didion, D. A. and Doyle, J. P. 1992. Evaluation Of Suction Line-Liquid Line Heat Exchanger In The Refrigeration Cycle. In proceeding: International Refrigeration and Air Conditioning Conference, Purdue University, Paper. 149: 131-139.

Klein, S. A., Reindl, D. T. and Brownell, K. 2000. Refrigerant System Performance Using Liquid-Suction Heat Exchangers. Int. J. Refrig. 23: 588-596.

Navarro-Esbri, J., Cabello, R. and Torrella, E. 2005. Experimental Evaluation Of The Internal Heat Exchanger Influence On A Vapor Compression Plant Energy Efficiency Working with R12, R134a and R407C. Energy. 30: 621-624.

Downloads

Published

2015-10-17

Issue

Section

Science and Engineering

How to Cite

THE EFFECT OF LIQUID SUCTION HEAT EXCHANGER SUB-COOLER ON PERFORMANCE OF A FREEZER USING R404A AS WORKING FLUID. (2015). Jurnal Teknologi (Sciences & Engineering), 76(11). https://doi.org/10.11113/jt.v76.5914