INSTRUMENTED PILE LOAD TESTING WITH DISTRIBUTED OPTICAL FIBRE STRAIN SENSOR
DOI:
https://doi.org/10.11113/jt.v77.6381Keywords:
Bored pile, Fibre-Optic sensing, BOTDA, maintain load testAbstract
An instrumented pile load test was conducted for a 1.2m diameter bored pile at Putrajaya to verify pile performance towards geotechnical design. This test pile was instrumented with new monitoring technique using distributed strain sensing known as Brillouin Optical Time Domain Analysis (BOTDA) and compared with conventional sensors, i.e. vibrating wire strain gauge, LVDT (linear variable differential transformer) and dial gauge. This manuscript includes the description of subsurface conditions consisting of weathered granitic residual soils, test pile installation and instrumentation setup of Maintain Load Test (MLT). Field measurement results such as the load transfer response and average unit shaft resistance using the distributed fibre optic strain sensor were well matched with the results using the conventional sensors. However, the distributed fibre optic strain sensor has the added advantage of detecting the localized defect such as pile necking, bending, and overall behaviour of bored pile effectively.Â
References
Klar, A., Bennett, P. J., Soga, K., et al. 2006.Distributed Strain Measurement For Pile Foundations. Proc. ICE, Geotech. Engng. 159(3):135–144.
Mohamad, H., Soga, K. and Bennett, P.J. 2009. Fibre Optic Installation Techniques For Pile Instrumentation. Proceedings of the 17th International Conference on Soil Mechanics on Soil Mechanics and Geotechnical Engineering: The Academia and Practice of Geotechnical Engineering. IOS Press. 3:1873-1876.
Mohamad, H., Soga K., Pellew, A. and Bennett, P.J. 2011. Performance Monitoring of a Secant Piled Wall Using Distributed Fiber Optic Strain Sensing. Journal of Geotechnical and Geoenvironmental Engineering. 137(12):1236-1243.
Mohamad, H., Bennett, P. J., Soga K., Mair, R J and Bowers, K. 2010. Behaviour Of An Old Mansonry Tunnel Due To Tunnelling Induced Ground Settlement. Géotechnique. 60(12): 927–938.
Soga, K., Mohamad, H. and Bennett, P.J. 2008. Distributed Fiber Optics Strain Measurements For Monitoring Geotechnical Structures. 6th International Conference on Case Histories in Geotechnical Engineering (Symposium in honor of Professor James K Mitchell). Arlington, USA.
ASTM D1143/D1143 – 07 (Reapproved 2013) Standard Test Methods for Deep Foundations Under Static Axial Compressive Load. ASTM International.
Savitzky, A. and Golay, M. J. E. 1964. Smoothing And Differentiation Of Data By Simplified Least Squares Procedures. Analyt. Chem. 36(8):1627–1639