A REVIEW OF SAFETY CONSTRUCTION OF BILLBOARD AROUND BANJARMASIN

Authors

  • Reza Adhi Fajar Banjarmasin State Polytechnic, Jalan Brigjend H.Hasan Basri Kayutangi 70124 Banjarmasin, Indonesia
  • Joni Irawan Banjarmasin State Polytechnic, Jalan Brigjend H.Hasan Basri Kayutangi 70124 Banjarmasin, Indonesia
  • Rinova Firman Banjarmasin State Polytechnic, Jalan Brigjend H.Hasan Basri Kayutangi 70124 Banjarmasin, Indonesia

DOI:

https://doi.org/10.11113/jt.v77.6698

Keywords:

Billboard, construction, safe, dimension, pillar

Abstract

A safe and standard billboard construction is very important everywhere as well as in and around Banjarmasin. Therefore, the research using cross-sectional descriptive design to analyze the ratio of axial-flexible stress of pillars was conducted. The inclusion criteria for the billboards are billboards with dimension of 4x6 m2, 5x10 m2 and cross-road horizontal billboard or Bando. Meanwhile the exclusion criteria are billboards with dimension of 2x4 m2, 1x1 m2 and non-steel materials billboards. The result shows that billboard construction that is considered safe as well as standard one is billboard with the dimension of 4x6 m2, 10†pillar, 5x5 cm2 angled steel profile; and five pillars Bando with 18†middle pillar, two f 10†side pillars (2.5†truss). Meanwhile billboard construction which is not considered safe are 5x10 m2 billboard, 18†pillar, 2â€truss, 5x5 cm2 angled steel profile; and Bando with three 18†pillars, 2†truss. The improvement for 5x10 m2 billboards is by adding 2†diagonal truss, 18†pillar, 2†truss; for three pillars Bando, the improvement is by adding four f 6†pillar, 18†pillar, 2.5†truss.   

References

Rokach J. 1991. Theory and Problems of Structural Steel Design. McGraw-Hill Inc. New York.

Warnitchai, P. et al. 2009. Wind Tunnel Model Test of Large Billboards, Advances in Structural Enginering. 12(1).

Smith, D.A. et al. 2014. Characteristics of Wind Induced Net Force and Torque on a Rectangular Sign Measured in The Field, Journal of Wind Engineering and Industrial Aerodynamics, USA

Mara, T.G. 2014. Influence of Solid Area Distribution on The Drag of a Two-Dimensional Lattice Truss, Journal of Engineering Mechanics. 140: 644-649.

Baheru et al. 2014. Distribution of Wind-Driven Rain Deposition on Low-Rise Building: Direct Impinging Raindrops Versus Surface Runoff, Journal of Wind Engineering and Industrial Aerodynamics USA.

Fajar R.A. et al. 2014. Structure Analysis of Billboard Construction around Banjarmasin. Final report of Fundamental research. The State Polytechnic of Banjarmasin, Banjarmasin.

Irawan, J. 2012, Problems and The Solution of Billboard Construction in Banjarmasin, Journal of Banjarmasin State Polytechnic, Banjarmasin. 4 (2): 2985-5761.

Downloads

Published

2015-12-13

How to Cite

A REVIEW OF SAFETY CONSTRUCTION OF BILLBOARD AROUND BANJARMASIN. (2015). Jurnal Teknologi, 77(23). https://doi.org/10.11113/jt.v77.6698