SIMULATION OF SINGLE CHANNEL BIOLOGICAL TISSUE SPECTROSCOPY USING COMSOL MULTIPHYSICS

Authors

  • Azmi Abou Basaif Biomedical Electronic Engineering, School of Mechatronic, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • Nashrul Fazli Mohd Nasir Biomedical Electronic Engineering, School of Mechatronic, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • Zulkarnay Zakaria Tomography Imaging Research Group, School of Mechatronic, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • Ibrahim Balkhis Tomography Imaging Research Group, School of Mechatronic, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • Shazwani Sarkawi Tomography Imaging Research Group, School of Mechatronic, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • Jurimah Abd Jalil Tomography Imaging Research Group, School of Mechatronic, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia

DOI:

https://doi.org/10.11113/jt.v77.6796

Keywords:

Magnetic Induction Spectroscopy (MIS), Foreign Metal, Phase Shift, Biological Tissue, COMSOL Multiphysics software

Abstract

The enhanced ability to detect accurate location and measure the depth of a   metal inside a biological tissue is very useful in the assessment of medical condition and treatment. This manuscript proposed a solution via the measurement of the tissue properties using magnetic induction spectroscopy (MIS) method to describe the characterization of biological soft tissue. The objective of this study is to explore the viability of locating embedded metal inside a biological tissue by measuring the differences the biological tissue electrical properties using principle of Magnetic Induction Spectroscopy (MIS). Simulation is done using COMSOL Multiphysics software for accurate information on the involved parameters for both metal and biological tissues. Simulation has confirmed that MIS capable of detecting and locate embedded metal inside a biological tissue.

References

N. Rozen, I. Dudkiewicz and P. Ballistics. 2011. Armed Conflict Injuries to the Extremities. London: Springer-Verlag.

H. Scharfetter, R. Casanas, and J. Rosell. 2003. Biological Tissue Characterization by Magnetic Induction Spectroscopy (MIS): Requirements And Limitations. IEEE Trans. Biomed. Eng. 50(7): 870-80.

Hevia-Montiel, N., Soto, E. S., Gonzalez-diaz, C. A. 2012. Early Breast Cancer Detection by Magnetic Induction Spectroscopy. Trans JAPANESE Soc Med ANDS Biol Eng. 51(1): 516.

A. Barai, S. Watson, H. Griffiths and R. Patz. 2012. Magnetic Induction Spectroscopy: Non-Contact Measurement of the Electrical Conductivity Spectra of Biological Samples. Meas. Sci. Technol. 23(8): 1-11.

Li, X., & He, B. 2010. Multi-excitation Magnetoacoustic Tomography with Magnetic Induction for Bioimpedance Imaging. IEEE Transactions on Biomedical Engineering. 29(10): 1759-1767.

A. Kangarlu and P. L. Robitaille. 2000. Biological Effects and Health Implications in Magnetic Resonance Imaging. Concepts in Magnetic Resonance. 12(5): 321-359.

Z. Zakaria, R. Abdul Rahim, M. S. B. Mansor, S. Yaacob, N. M. N. Ayub, S. Z. M. Muji, M. H. F. Rahiman, and S. M. K. S. Aman. 2012. Advancements in Transmitters and Sensors for Biological Tissue Imaging in Magnetic Induction Tomography. Sensors Basel. 12(6): 7126-7156.

J. Sun, G. Jin, M. Qin, Z. Wan, J. Wang, W. Guo, L. Xu, X. Ning, J. Xu, X. Pu, M. Chen and H. Zhao. 2012. The Detection of Chronic Cerebral Hemorrhage in Rabbits With Magnetic Induction. J. Phys. Conf. Ser. 407(1): 1-10.

J. Y. Wong and J. D. Bronzino. 2007. The Relationship of Materials Characteristic to Biologic Properties. Biomaterials Handbook, Taylor & Frances Group, Ed. Boca Raton, FL: CRC Press. 129-160.

M. Rudin. 2005. Imaging Techniques. Molecular Imaging Handbook: Basic Principle and Application in Biomedical Research. London WC2H 9HE: Imperial College Press. 45-128.

Downloads

Published

2015-12-16

Issue

Section

Science and Engineering

How to Cite

SIMULATION OF SINGLE CHANNEL BIOLOGICAL TISSUE SPECTROSCOPY USING COMSOL MULTIPHYSICS. (2015). Jurnal Teknologi, 77(28). https://doi.org/10.11113/jt.v77.6796