A CFD SIMULATION OF PM1 AND CO AIR CONTAMINANTS IN A BUS PASSENGER COMPARTMENT

Authors

  • Noor Emilia Ahmad Shafie Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Haslinda Mohamed Kamar Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Nazri Kamsah Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia

DOI:

https://doi.org/10.11113/jt.v77.6863

Keywords:

Computational fluid dynamics, Indoor air contaminant, ventilation system, bus passenger compartment

Abstract

Air distribution systems inside a bus compartment are important for providing healthy and comfortable environment for passengers. Lack of ventilation inside the bus passenger compartment causes an increase level of air contaminants concentration. Particulate matters and carbon monoxide are indoor air contaminants which can affect the passenger’s health such as respiratory problem and lung cancer. This article reports the results of a CFD simulation on transport of carbon monoxide and particulate matter 1 inside a passenger compartment of a university’s shuttle bus. Fluent CFD software was used to develop a simplified three-dimensional model of the bus passenger compartment. Flow analysis was carried out using RNG k-e turbulent model for air flow, discrete phase and species transport for the air contaminants. Four variations of ventilation system namely two mixing ventilation types, combined mixing with displacement ventilation and combined mixing ventilation with underfloor air distribution was examined. The CFD simulation results show that the use of the combined mixing and displacement ventilation and also the combined mixing and underfloor ventilation types are capable of reducing the concentration of carbon monoxide and particulate matter 1 inside the bus passenger compartment by 81% and 54%, respectively.

References

Ho, S. H., Rosario, L. & Rahman, M. M. 2011. Comparison of Underfloor and Overhead Air Distribution Systems in an Office Environment. Building and Environment. 46: 1415-1427.

Lin, Z., Chow, T. T., Tsang, C. F., Fong, K. F. & Chan, L. S. 2005. CFD Study on Effect of the Air Supply Location on the Performance of the Displacement Ventilation System. Building and Environment. 40: 1051-1067.

Zhu, S., Demokritou, P. & Spengler, J. 2010. Experimental and Numerical Investigation of Micro-Environmental Conditions in Public Transportation Buses. Building and Environment. 45: 2077-2088.

Fluent, A. N. S. Y. S. 2012. 14 User Manual. ANSYS Inc. New York.

Handbook, A. S. H. R. A. E. 2013. Fundamentals 2013. Atlanta, USA: ASHRAE.

Bari, S. & Naser, J. 2010. Simulation of Airflow and Pollution Levels Caused by Severe Traffic Jam in a Road Tunnel, Tunnelling and Underground Space Technology. 25: 70-77.

World Health Organization. 2006. Regional Office for Europe, & World Health Organization. Air Quality Guidelines: Global Update 2005: Particulate Matter, Ozone, Nitrogen Dioxide, And Sulfur Dioxide. World Health Organization.