IAQ ASSESSMENT IN UPNM MEDICAL CENTER

Authors

  • Khairunnisa Ahmad Department of Electrical and Electronics, Faculty of Engineering, National Defence University of Malaysia
  • Chew Sue Ping Department of Electrical and Electronics, Faculty of Engineering, National Defence University of Malaysia

DOI:

https://doi.org/10.11113/jt.v77.6991

Keywords:

Indoor air quality, WSN, labview

Abstract

The number of cases involving human death has increased due to scattered virus in the air. This has become a major concern on air quality, especially indoor air quality. The chemical compounds found in the building have limited exchange of outdoor and indoor, which results in building of contaminants such as CO2 emitted by occupants activity in the building. The usage of air conditioner is unable to removes pathogens because its only circulates in air within the area. Medical Centre has a very high potential to centralize the patient with diseases related to health problems such as asthma, respiratory and cardiovascular related-diseases. This study is conducted at medical centre of NDUM, in Kuala Lumpur. The number of patients admitted was compared to the level of CO2, temperature and relative humidity in the Medical Centre. The outdoor air index is collected from DOE Malaysia. Wireless Sensor Network (WSN) is used in this system as it can collect and disseminate the environmental data. Zigbee with 2.4GHz band is used as the wireless standard for the measurement. Sensors were attached to several points at the wall of the waiting room and were controlled by the PC module. Lab View is used to manage the data acquisition due to its ability to program a real-time system. The collected data of temperature, relative humidity and level of C02 determined the indoor air quality in the medical centre. This study brought to the assessment on the medical practice and the air quality that met the standard suggested by ASHRAE.

References

E. Kabir, K. H. Kim, J. R. Sohn, B. Y. Kweon, and J. H. Shin. 2012. Indoor Air Quality Assessment in Child Care and Medical Facilities in Korea. Environment Monit Assess. 15.

J. Yang, K. T. Chan, X. Wu, and X. Yang. 2010. Investigation of Indoor Air Quality in the Underground Shopping Mall. IEEE.

A. A. S. 62.1-2007. 2008. Ventilation for Acceptable Indoor Air Quality. 1-18.

H. I. C. P. a. D. Division. Health Facts 2012. July 2012.

K. Qudiesat, K. Abu-Elteen, A. Elkarmi, M. Hamad, and M. Abussaud. 2009. Assessment of airborne pathogens in heatlhcare settings. African Journal of Microbiology Research. 3: 066-076.

G.-H. Wan, F.-F. Chung, and C.-S. Tang. 2011. Long Term Surveillance of Air Quality in Medical Center Operatign Rooms. AJIC Journal. 39: 7.

[E. G. Dascalaki, A. Lagoudi, C. A. Balaras, and A. G. Gaglia. 2007. Air Quality in Hospital Opearting Rooms. Building and Environement. 43: 8.

C.-C. Jung, P.-C. Wu, C.-H. Tseng, and H.-J. Su. 2015. Indoor air quality varies with ventilation types and working areas in hospitals. International Journal of Building Science and Its Application. 6.

S. N. Alpat, G. Usluer, I. Ozgunes, E. D. Kartal, and N. Erben. 2012."Clinical and Epidemiological Characteristics of Hospitalized Patients with 2009 H1N1 Influenza Infection. Hindawi Publishing Corporation Influenza Research and Treatment. 2012: 5.

B. A. A. Yousef, A. A. D. Elshareef, M. A. K. Ibraheem, and S. S. Alsayed. 2013. Assessment of Indoor Air Quality In Medical Facilities in Sudan. International Journal of Scientific and Technology Research. 2: 4.

S. Conti, A. Lafranconi, A. Zanobetti, C. Fornari, F. Madotto, J. Schwartz, et al. 2015. Cardiorespiratory treatments as modifiers of the realationship between particulate matter and health: A case-only analysis on hospitalized patients in Italy. Journal of Environemental Science, Ecology and Public Health. 136.

F. W. Akashah, A. S. Ali, and S. F. M. Zahari. 2015. "Post-Occupancy Evaluation (POE) of Conventional-Desinged Buildings: The Effects of Occupants Comfort on Productivity. Jurnal Teknologi. 75: 10.

(2013, June 29). Composition of the Atmosphere. Available: https://www.nc-climate.ncsu.edu/edu/k12/.AtmComposition.

N. Y. Y. Razali, M. T. Latf, D. Dominick, N. Mohamad, F. R. Sulaiman, and T. Srithawirat. 2014. Concentration of Particulate Matter, CO and CO2 in Selected Schools in Malaysia. International Journal of Buiding Science and its Application. 31.

J.R. Turpin. 2015. Defining Indoor Air Quality." www.archnews.com.

U.s.E.A.U.S EPA. 2014. Air Quality Index: A Guide to Air Quality and Your Health.

T. H. Koep, F. T. Enders, C. Pierret, S. C. Ekker, D. Krageschmidt, K. L. Neff, et al. 2013. Predictors of Indoor Abolute Humidity and Estimated Effects on Influenza Virus Survival in Grade School," BMC Infectious Diseases. 8.

A. A. S. 2004. 55-2004. ASHRAE Standard Thermal Conditions for Human Occupancy. 1-5.

K. K. Khedo, R. Perseedoss, and A. Mungur. 2010. A Wireless Sensor Network Air Pollution Monitoring System. International Journal of Wireless & Mobile Networks (IJWMN). 2: 15.

D. N. Tambe and N. A. Chavhan. 2013. Performance of IEEE 802.15.4 in WSN for Monitoring Real Time Air Pollution Parameters. International Journal of Computer Science and Network. 2: 61-66.

T. K. M, R. S.S, and A. G.M. 2011. Monitoring of Air Pollution using Wireless Sensors- A Case Study of Monitoring air polluton in Nagpur city. International Juornal of Environment Sciences. 2: 10.

B. Chamberlain, C.-F. B. ISD, and G. Jordan, 2012. Applications of WSN In Monitoring Indoor Air Quality in the Classroom Environment. National Science Foundation, Research Experiences for Teachers Program 2012. 33.

J. Lozano, J. I. Suarez, P. Arroyo, J. M. Ordales, and F. Alvarez. 2012. Wireless Sensor Network For Indoor Air Quality Monitoring." Chemical Engineering Transactions.30: 319-324.

A. R. Kasar, D. S. Khemnar, and N. P. Tembhurnikar. 2013. WSN Based Air Pollution Monitoring System. International Journal of Science and Engineering Applications. 2: 55-59

P. V. Raju, R. V. R. S. Aravind, and B. S. Kumar. 2013. Pollution Monitoring System using Wireless Sensor Network in Visakhapatam. Journal of Engineering Trends and Technology (IJETT). 4: 5.

Downloads

Published

2015-12-29

How to Cite

IAQ ASSESSMENT IN UPNM MEDICAL CENTER. (2015). Jurnal Teknologi, 77(32). https://doi.org/10.11113/jt.v77.6991