Test Cell For Polarization And Depolarization Current Test Of Transformer Insulation Oil

Authors

  • Nor Asiah Muhamad
  • Toan Phung
  • Trevor Blackburn

DOI:

https://doi.org/10.11113/jt.v54.820

Abstract

Polarisasi dan depolarisasi Arus (PDA) analisis biasanya digunakan untuk menentukan kadar air dalam di antara penebat minyak–kertas dan juga konduktiviti minyak di dalam pemboleh ubah. Pengukuran PDA ke atas pemboleh ubah di tapak dilakukan dengan menyuntikkan Voltan DC pada satu sisi pemboleh ubah dan pengukuran arus akak dilalukan pada sisi yang lain, di mana semasa pemdukuran dijalankan pemboleh ubah ini harus dipisahkan dari operasi. Ujian PDC biasanya berjalan sehingga 10000s untuk polarisasi dan harus menunggu 10000s lagi untuk pengukuran depolarisasi. Kerana tempoh ujian yang lama, aplikasi kaedah ini untuk memantau pemboleh ubah yang sedang beroperasi menjadi kurang popular. Dalam kajian ini, sel direka dan dibangunkan untuk melakukan ujian PDA pada sampel minyak penebat. Pola PDA minyak penebat diperoleh dengan ujian menggunakan sel tersebut didapati memiliki pola yang sama dengan ujian dilakukan di tapak. Ramalan kondisi pemboleh ubah dalam perkhidmatan dapat dilakukan dengan melakukan ujian PDA pada sampel minyak penebat yang diambil dari tangki pemboleh ubah dan kemudian membandingkan polanya, tahap konduktiviti dan nilai pemuat berkadar terhadap pola asal PDA minyak penebat tersebut. Kata kunci: Polarisasi; depolarisasi; minyak penebat; pemboleh ubah dan sel Polarization and Depolarization Current (PDC) analysis is normally used to determine the water content in the oil–paper insulation barrier and also oil conductivity inside the transformers. PDC measurement onsite was performed by injecting the DC Voltage at one side of the transformer and current measurement will be carried at the other side of the transformer, in which the transformers are required to be isolated from services to be tested. PDC test normally run up to 10000s for polarization and had to wait for other 10000s for depolarization measurement. Because of the long duration of the test, applications of this method to monitor transformer on service become less popular. In this research, a cell was designed and developed to perform PDC on insulation oil samples. The PDC pattern of insulation oil obtained by testing using the cell was found to have same pattern with the test done onsite. Predictions for transformers in service can be made by performing PDC tests on oil samples taken from the transformer tank and then comparing its pattern, conductivity level and measured capacitance value against a PDC fingerprint. Key words: Polarization; depolarization; oil insulation; transformer; cell

Downloads

Published

2012-03-08

Issue

Section

Science and Engineering

How to Cite

Test Cell For Polarization And Depolarization Current Test Of Transformer Insulation Oil. (2012). Jurnal Teknologi, 54(1), 343–359. https://doi.org/10.11113/jt.v54.820