RETROFITTING PERFORMANCE OF REINFORCED CONCRETE ONE WAY SLAB

Authors

  • Norliyati Mohd Amin Institut Infrastructure Engineering and Sustainable Management (IIESM), Faculty of Civil Engineering (FCE), Universiti Teknologi MARA, 40450, Shah Alam, Selangor, Malaysia
  • Nur Aqilah Aziz Institut Infrastructure Engineering and Sustainable Management (IIESM), Faculty of Civil Engineering (FCE), Universiti Teknologi MARA, 40450, Shah Alam, Selangor, Malaysia
  • Ilya Joohari Institut Infrastructure Engineering and Sustainable Management (IIESM), Faculty of Civil Engineering (FCE), Universiti Teknologi MARA, 40450, Shah Alam, Selangor, Malaysia
  • Anizahyati Alisibramulisi Institut Infrastructure Engineering and Sustainable Management (IIESM), Faculty of Civil Engineering (FCE), Universiti Teknologi MARA, 40450, Shah Alam, Selangor, Malaysia

DOI:

https://doi.org/10.11113/jt.v78.8509

Keywords:

Concrete, Crack, Retrofit and Strengthening, Epoxy injection, Carbon Fiber Reinforced Polymer, Patch

Abstract

Cracks in concrete structure have always been a big threat on the strength of the concrete. Crack is one of the common deterioration observed in reinforced concrete beams and slabs. Concrete cracking is a random process, highly variable and influenced by many factors. To restore the structural capacity of the concrete damages, retrofitting and strengthening are required. There are several techniques that are used for retrofitting and strengthening reported in the literature [1], [2], [3]. This paper investigates the strength performance of retrofitting and strengthening methods of reinforced concrete one-way slab. Flexural bending test are performed on three different concrete slab of size 1000 mm x 500 mm x 75 mm. The methods that are used for retrofit are epoxy injection and patching and for the strengthening is lamination of carbon fiber reinforced polymer. The slabs were loaded to a certain stage where the cracks were formed for retrofitting and strengthening procedure. The achieved failure mode and load capacity of the concrete slab were observed. The repaired techniques for restoring and improving the structural capacity of cracked concrete slabs were analyzed. The ultimate load achieved for the epoxy injection laminate was 19.60 kN followed by CFRP laminate and patching that were 17.64 kN and 17.03 kN respectively. While the deflection value for the three specimens were 14.42 mm, 4.49 mm and 7.036 mm.  

References

Eom, S., J., Jang, W. and Kim, S. 2015. Managing Concrete Crack Information through Correction of the Slab Rebar Arrangement based on Six Sigma. Journal of Civil Engineering. 1-9.

Wipf, T., J., Klaiber, F., W. and Raker, E., J. 2004. Effective Structural Concrete Repair. Evaluation of Repair Materials for Use in Patching Damaged Concrete. Iowa Department of Transportation Highway Division and the Iowa Highway Research Board.

Nikopour, H. and Nehdi, M. 2011. Shear Repair Of RC Beams Using Epoxy Injection And Hybrid External FRP. Materials and Structures. 44: 1865-1877.

Carpinteri, A. 1999. Minimum Reinforcement in Concrete Members. Elsevier Science Ltd, The Boulevard, Langford Land Kidlington, Oxford OX5 1GB, UK.M. Young, The Technical Writer’s Handbook. Mill Valley, CA: University Science, 1989.

Carino, N., J. and Clifton, J., R. 1995. Prediction of Cracking in Reinforced Concrete Structures. Department Of Commerce, United State of America.

Katsumata, H., Kimura, K. and Kobatake, Y. 1996. Seismic Retrofitting Technique Using Carbon Fibers for Reinforced Concrete Buildings. Fracture Mechanics of Concrete Structures. Technical Research Institute, Obayashi Corporation, Japan. MeIntyre, D. 2002. Color Blindness. Dalton Publishing.

Downloads

Published

2016-05-08

How to Cite

RETROFITTING PERFORMANCE OF REINFORCED CONCRETE ONE WAY SLAB. (2016). Jurnal Teknologi (Sciences & Engineering), 78(5-3). https://doi.org/10.11113/jt.v78.8509