TEMPERATURE RISE OF COLD-FORMED STEEL BUILT-UP BACK-TO-BACK COLUMN UNDER STANDARD FIRE

Authors

  • Fadhluhartini Muftah Faculty of Civil Engineering, Universiti Teknologi Mara Pahang, Pahang, Malaysia
  • Mohd Syahrul Hisyam Mohd Sani Faculty of Civil Engineering, Universiti Teknologi Mara Pahang, Pahang, Malaysia
  • Shahrin Mohammad Faculty of Civil Engineering, Universiti Teknologi Malaysia, Johor, Malaysia
  • Shek Poi Ngian Faculty of Civil Engineering, Universiti Teknologi Malaysia, Johor, Malaysia
  • Mahmood Md Tahir Faculty of Civil Engineering, Universiti Teknologi Malaysia, Johor, Malaysia

DOI:

https://doi.org/10.11113/jt.v78.8526

Keywords:

Cold-formed steel, Standard ISO 834 fire, Critical temperature, Critical time

Abstract

Cold-formed steel (CFS) has been used for various applications in building structure. Due to its many advantages, the uses of CFS can be widened to build new or to renovate existing single one or two families private homes. However, the fire resistance of the CFS is a critical issue whereby inclined to lose its vigour when it is exposed to fire, compared to hot-rolled steel member. This study takes the opportunity to investigate the application of this material as column members subjected to the standard fire. Four columns were tested. One column with a static load was tested under the ambient condition, while the three other columns were loaded at different degrees of utilisation under the standard ISO 834 fire conditions. The increases of temperature on the column surface were monitored using thermocouple Type K and the analyses of this thermocouple reading was taken to evaluate the mean temperature of the column. The temperature behaviours of back-to-back column for all degrees of utilisation showed that, the web was a lower temperature compared to the flange due to the greater thickness of the web. Meanwhile, the failure temperature of the CFS could reach up to 651.0 ºC for 30.0 % degree of utilisation with 8.0 minutes of resistant time.

References

Robert Moran. 2011. Identifying Lightweight Construction. Fire Engineering. [Online]. From:

http://www.fireengineering.com/articles/print/volume-164/issue4/departments/fireprevention_bureau/identifying-lightweight-construction.html. [Accessed on 21 October 2015].

Ranawaka, T. and Mahendran, M. 2009. Distortional Buckling Tests Of Cold-Formed Steel Compression Members At Elevated Temperatures. Journal of Constructional Steel Research. 65(2): 249-259.

Chen, J. and Young, B. 2007. Cold-Formed Steel Lipped Channel Columns At Elevated Temperatures. Engineering Structures. 29(10): 2445-2456.

Feng, M., Wang, Y. C. and Davies, J. M. 2004. A Numerical Imperfection Sensitivity Study Of Cold-Formed Thin-Walled Tubular Steel Columns At Uniform Elevated Temperatures. Thin-Walled Structures. 42(4): 533-555.

Feng, M., Wang, Y. and Davies, J. 2003. Structural Behaviour Of Cold-Formed Thin-Walled Short Steel Channel Columns At Elevated Temperatures. Part 1: experiments. Thin-Walled Structures. 41(6): 543-570.

Feng, M., Wang, Y. and Davies, J. 2003b. Structural Behaviour Of Cold-Formed Thin-Walled Short Steel Channel Columns At Elevated Temperatures. Part 2: Design Calculations And Numerical Analysis. Thin-Walled Structures. 41(6): 571-594.

Feng, M., Wang, Y. C. and Davies, J. M. 2003c. Axial Strength Of Cold-Formed Thin-Walled Steel Channels Under Non-Uniform Temperatures In Fire. Fire Safety Journal. 38(8): 679-707.

Kaitila, O. 2002. Imperfection Sensitivity Analysis Of Lipped Channel Columns At High Temperatures. Journal of Constructional Steel Research. 58(3): 333-351.

Kankanamge, N. D. 2010. Structural Behavior And Design Of Cold-Formed Steel At Elevated Temperature. Thesis. Queensland University of Technology.

Chen, J. and Young, B. 2007b. Cold-Formed Steel Lipped Channel Columns At Elevated Temperatures. Engineering Structures. 29(10): 2445-2456.

Moura Correia, A. J. P., Rodrigues, J. P. C. and Gomes, F. C. T. 2013. A Simplified Calculation Method For Fire Design Of Steel Columns With Restrained Thermal Elongation. Computers And Structures. 116: 20-34.

Li, G. Q., Wang, P. and Wang, Y. 2010. Behaviour and design of restrained steel column in fire, Part 1: Fire test. Journal of Constructional Steel Research. 66(8-9): 1138-1147.

Craveiro, H. D., Rodrigues, J. P. C. and Laím, L. 2014. Cold-Formed Steel Columns Made With Open Cross-Sections Subjected To Fire. Thin-Walled Structures. 85: 1-14.

BS EN 13381-4. 2013. BSI Standards Publication Test Methods For Determining The Contribution To The Fire Resistance Of Structural Members Part 4 : Applied Passive Protection To Steel Members.

BS EN 1363-1. 2012. BSI Standards Publication Fire resistance tests Part 1 : General Requirements.

ISO. 834-1. 1999. Fire Resistance Tests – Elements Of Building Construction, Part 1: general requirements. Geneva, Switzerland: International Organization for Standardization (ISO).