FOUNDATION MODELLING FOR COOLING WATER PUMP MACHINE IN PT PUPUK SRIWIJAYA (PURSI) II-B PROJECTS

Authors

  • Ratna Dewi Civil Engineering Department, Sriwijaya University, Palembang, South Sumatera, Indonesia
  • Yulia Hastuti Civil Engineering Department, Sriwijaya University, Palembang, South Sumatera, Indonesia
  • Agnes Mentari Civil Engineering Department, Sriwijaya University, Palembang, South Sumatera, Indonesia

DOI:

https://doi.org/10.11113/jt.v78.9605

Keywords:

Machine, foundation, frame foundation, pump machine, damping ratio

Abstract

PT Pupuk Sriwijaya (PUSRI) in Palembang, South Sumatera, Indonesia uses a lot of machines to run the fabric.  One of the project is PUSRI II-B, which use cooling water pump machine. The machine will not operate properly if it does not use the appropriate foundation to support static and dynamic loads. The Terzaghi and Meyerhof methods were used in static analysis to measure the settlement in the pile group and soil bearing capacity.  The frequency, damping, and vibration amplitude of the vibration that occur in a vertical and horizontal vibration, and the vibration rocking were calculated by using the trial error method for dynamic analysis.  Modelling frame foundation machine is the main focus in this research. The result shows that the most effective foundation dimension for cooling water pump machine is frame foundation type with the pile cap dimensions of 9.8 m x 4 m x 1.5 m; column of 0.5 m x 0.5 m x 1 m and slab of 9.8 m x 4 m x 0.3 m, and using the piles with a diameter of 0.35 m, length of 21 m and the spacing between the piles is about 2.45 m.  The gravel was compacted to the same level where the pile cap was planned in order to increase the soil shear modulus.  

References

Irsyam, M. 2008. Dinamika Tanah dan Fondasi Mesin, ITB, Bandung.

Srinivasulu, P and Vaidyanathan, C.V. 1978. Handbook of Machine Foundations, Tata Mc Graw-Hill Publishing Co. LTD, New Delhi.

Prakash, S. and Puri, V.K., 1988. “Foundations for Machines: Analysis and Designâ€, John Wiley & Sons, New York, U.S.A.

Fattah, M.Y., Al-Azal, A.A., Al-Badri, H.T., 2007, “Design Charts For Machine Foundationsâ€, Journal Of Engineering. 13(4)

Arya, S., O’neill, M., and Pincus, G. 1981. Design of Structures and Foundations for Vibrating Machines, Gulf Publishing Company Book Division, Houston.

Swami, S., 1999, “Soil Dynamics and Machine Foundationâ€, Galgotia Publications Private Limited, New Delhi

Das, B. M. 2008, Advanced Soil Mechanics (3th Edition), Taylor & Francis Group, New York.

Jayarajan P., Kouzer K.M., “ Dynamic Analysis of Turbo-generator Machine Foundationsâ€. Journal of Civil Engineering and Environmental Technology, 1(4): 30 -35.

Bhatia, K.G, 2008, “Foundation For Industrial Machines and Earthquake Effects’, ISET Journal of Earthquake Technology., 45(1-2): 13–29.

Bhatia, K.G. (2008). “Foundations for Industrial Machines—A Handbook for Practising Engineersâ€, D-CAD Publishers, New Delhi

Ramdasa, K., Singh, A.K. and Bhatia, K.G., 1982, “Dynamic Analysis of Frame Foundation Using FEMâ€, Proceedings of the 7th Symposium on Earthquake Engineering, Roorkee. 1: 411–416

Bowles, J.E, 1988, “Foundation Analysis And Design (4th Edition), Mc Graw-Hill, New York

Prakash, S., 1981, “Soil Dynamicsâ€, McGraw-Hill Book Company, New York, U.S.A

Richart, F.E. Jr. , 1962, “ Foundation vibrations, Trans, ASCE, part 1, pp. 863 – 898

American Society for Testing and Materials, Annual Book of ASTM Standard, D1. 143-81

Downloads

Published

2016-08-25

Issue

Section

Science and Engineering

How to Cite

FOUNDATION MODELLING FOR COOLING WATER PUMP MACHINE IN PT PUPUK SRIWIJAYA (PURSI) II-B PROJECTS. (2016). Jurnal Teknologi (Sciences & Engineering), 78(8-5). https://doi.org/10.11113/jt.v78.9605