ASSESSMENT OF BUILDINGS FOR SEISMIC RESISTANCE
DOI:
https://doi.org/10.11113/mjce.v23.15812Keywords:
Earthquake, Types of Buildings, Resistance, Retrofit, SurveyAbstract
The recent earthquakes in India and different parts of the world have caused loss of human lives and damage to property due to the collapse of structures. Though an earthquake cannot be prevented, the loss of life and property can be minimized by taking necessary steps on the existing structures to reduce the damages. The seismic codes contain provisions for planning and designing earthquake resistant structures. It becomes essential to carry out a survey and identify existing structures that are deficient and carry out appropriate retrofit. This study first identifies the earthquake resistant features stipulated by the seismic codes for buildings. Then a survey assessment carried in the district of Kollam (Kerala, India) is reported. Kollam is in moderate seismic risk zone, in the seismic zone map prepared by the Bureau of Indian Standards. This city deserves attention owing to high concentrations of population. Each area differs from one another in terms of climate, culture, methods of construction and living standards. Materials used for construction also differ. The localized survey has found out the methods of construction, materials used for construction and general pattern of the structures in Kollam city. Structures that are prone to damage during a seismic event were identified. Recommendations are given based on the guidance available in seismic codes and other references for retrofitting such structures.References
ACI 530 -88/ ASCE 5-88 1988 Building code requirements for masonry structures, ASCE, New York.
Agrawal S.K and A. Chourasia, Estimation of Seismic Vulnerability of Buildings in Delhi Municipal Area, Central Building Research Institute, Roorkee, India. From website on 03-
-2011: nidm.gov.in/idmc/.../A1-11 Shailesh%20Kr%20Agrawal.pdf
Alam M.J.B., M.A. Ansary, M.S. Rahman, Z. Uddin Ahmed, A.B.A. Imtiaz and M.M. Hossain (2007) Assessment of Vulnerability of Critical Infrastructures due to Earthquake in Sylhet City and Management, Proceedings of Pakistan Academy of Sciences, 44(3), 197-200.
Arya, A.S., 2008, Seismic Assessment of Masonry Buildings, Journal of South Asia Disaster Studies,1, 1, 23-43.
ASCE/SEI 31-03 ASCE Standard for Seismic Evaluation of Existing Buildings.
Bhattacharya, S.N., and Dattatrayam, R.S., 2002, EQ sequence in Kerala during Dec 2000 and Jan 2001", Current Science, 82,10, pp. 1275 – 1278. 25 May.
Bhupesh.S., Santhosh Unni.V, Hussain.M., Abhilash.B and Usha Kumari.T.S, Seismic Risk Assessment Of Existing Buildings In Kollam Corporation Limits, UG Project Report, Kerala University.
Brzev,S., 2004, Unreinforced brick masonry buildings with reinforced concrete roof slab, World Housing Encyclopedia report.
BS EN 1998-1:2004 Eurocode 8: Design of structures for earthquake resistance – Part 1: General rules, seismic actions and rules for buildings
BS EN 1998-1:2005, Eurocode 8 Design of structures for EQ resistance Part 1: General Rules, seismic actions and rules for buildings
BS EN 1998-3:2005, Eurocode 8 Design of structures for EQ resistance Part 3: Assessment and retrofitting of buildings
IIT Roorkee, 2006, Earthquake Risk Management, Lecture Notes, Department of Earthquake Egineering, India.
IMD (India Meteorological Department), Lodhi Road, New Delhi. http://www.imd.gov.in/section/seismo/static/welcome.htm
IS -13828-1993, Improving earth quake resistance of low strength masonry buildings.
IS 13935 Draft 2006, Guidelines for repair, restoration, condition assessment and seismic strengthening of masonry buildings.
IS -1893-Part 1 2002, Criteria for earth quake resistant design of structures- General Provisions and Buildings.
IS -4326-1993, Earth quake resistant design and construction and buildings-code of practice.
Kamatchi P., K. Balaji Rao, S.Arunachalam and N.R. Iyer (2011) Methodologies for Vulnerability Assessment of Built Environment subjected to Earthquakes, International
Journal of Earth Sciences and Engineering, 4,6 SPL, pp. 183-188.
NBCC 1990, National Building Code of Canada, National Research Council of Canada, Ottawa, Ontario, Canada.
Paul, D.K.,Yogendra Singh, and Ruhela, M.K., 2002, Guidelines for Earthquake resistant buildings, Department of Earthquake Engineering, IIT Roorkee.
Rai,D.C., Review of Documents on Seismic Evaluation of Existing Buildings, Department of Civil Engineering, Indian Institute of Technology Kanpur India
Sadat, M.R., M.S. Huq and M.A. Ansary, 2010, Seismic Vulnerability Assessment of Buildings of Dhaka City, Journal of Civil Engineering, IEB, 38,2, 159-172.
Srikanth, T., R.P. Kumar, A.P. Singh, B.K. Rastogi and S.Kumar (2010) Earthquake Vulnerability Assessment of Existing Buildings in Gandhidham and Adipur Cities in
Kachchh, Gujarat, India, European Journal of Scientific Research, 41,3,pp.336-353.
UCBC 1991 Uniform Code for Building Conservation, International Conference of Building Officials, Whittier, California.