GUST RESPONSE ANALYSIS OF OVERHEAD TRANSMISSION LINES FOR INTERPRETATION OF WIND-INDUCED VIBRATIONS MEASURED IN THE FIELD

Authors

  • Md. Robiul Awall Department of Civil Engineering, Rajshahi University of Engg. & Technology, Rajshahi, Bangladesh
  • Hiroki Yamaguchi Graduate School of Science and Engineering, Saitama University, Japan
  • Tasnuva Humyra Department of Civil Engineering, Rajshahi Science & Technology University, Natore, Bangladesh

DOI:

https://doi.org/10.11113/mjce.v27.15929

Keywords:

Overhead transmission line, gust response, finite element method, eigenvalue analysis, resonance, torsional response

Abstract

Several accidents occurred in bundle conductor overhead transmission lines due to large amplitude wind induced vibrations. In evaluating possible causes of these accidents and to develop appropriate counter measures, it is important to have a clear interpretation of the nature of vibrations which actually occurs in the field. This study is carried out to interpret large amplitude field measured wind induced vibrations based on gust response analysis of overhead transmission lines. Time average characteristics of field measured wind-induced vibrations have been discussed based on spectral analysis and time series acceleration. Eigenvalue analysis results of developed three dimensional finite element (FE) model of transmission lines has been discussed with dominant frequency of field measured response spectrum. Wind force has been modeled based on field measured characteristics of wind. Gust response of transmission lines has been evaluated by using developed finite element model of transmission lines and discussed with field measured vibrations. Results from field measured data analysis and eigenvalue analysis showed that cause of large amplitude vertical vibration does not happen due to resonance and galloping of transmission line-A. In case of transmission line-B, some events are found due to resonance and others events have a possibility of galloping as well as gust responses. Random peaks have been observed in time series acceleration which implies impulsive response and well confirmed with numerically obtained gust responses by using FE analysis. Suspension span are more prone in torsional response which are well confirmed with numerical results

References

American Society of Civil Engineers (1990) Guidelines for transmission line structural loading, ASCE manual and reports on engineering practice. 74, ASCE New York.

ANSYS (2005) ANSYS release 10.0 documentations. ANSYS Inc., USA.

Blakey, K. (1993) MSC/NASTRAN Basic Dynamic Analysis User’s Guide: version 68, MacNeal-Schwendler Corporation.

Clough, R.W. and Penzien, J. (1993) Dynamics of Structures, Second edition: McGraw-Hill Book Co., Inc., New York, USA.

Dempsey, D. and White, H. (1996) Winds wreak havoc on lines. Transmission and Distribution World, 48(6): 32-37.

Gurung, C.B., Yamaguchi, H. and Yukino, T. (2002) Identification of large amplitude windinduced vibration of ice-accreted transmission lines based on field observed data. Engineering Structures, 24:179-188.

Gurung, C.B., Yamaguchi, H. and Yukino, T. (2003) Identification and characterization of galloping of Tsuruga test line based on multi-channel modal analysis of field data. Journal of

Wind Engineering & Industrial Aerodynamics, 91:903-924.

Holmes, J.D. (2007) Wind loading of structures, Second edition, New York: Taylor & Francis.

Keyhan, H. McClure, G. and Habashi, W.G. (2013) Dynamic analysis of an overhead transmission line subject to gusty wind loading predicted by wind–conductor interaction.

Computers Structures, 122:135–144.

McCarthy, P. and Melsness, M. (1996) Severe weather elements associated with September 5, 1996 hydro electric failures near Grosse Isle, Manitoba, Canada. Manitoba Environmental

Service Centre, Environment Canada, 21.

Miguel, L.F.F, Riera, J.D., Joao, Kaminski, Menezes, R.C.R. (2012) Assessment of code recommendations through simulation of EPS wind loads along a segment of a transmission line. Engineering Structures, 43:1–11.

Ohkuma, T. and Marukawa, H. (1999) Galloping of overhead transmission lines in gusty wind. First International Conference on Advance in Structural Engineering and Mechanics, Seoul,

Korea, 71-76.

Pasha, M.A. (1989) How to tame galloping of transmission conductors. Electric world, 203(7):43-46.

Rawlins, C.B. (1978) Transmission lines reference book: wind-induced conductor motion, Chapter 4- Galloping conductors, EPRI Res. Project 795, 113-168 pp.

Ruoqiang, F., Yan, G. and Jinming, G. (2012) Effects of high modes on the wind-induced

response of super high-rise buildings. Journal of Earthquake Engineering and Engineering Vibration, 11(3): 427-434.

Simiu, E. and Scanlan, R.H. (1996) Wind Effects on Structures, New York: John Wiley & Sons.

Xuanyi, Z., Zhihui, H., Ming, G., An-an, Z., weiyu, Z. and Wei, F. (2013) Research on windinduced responses of a large-scale membrane structure. Journal of Earthquake Engineering

and Engineering Vibration, 12(2): 297-305.

Yamaguchi, H. and Gurung, C.B. (2005) Characterization of wind-induced vibrations in transmission lines by single-channel field data analysis. Wind and structures, 8(2):1-14.

Yamaguchi, H. and Xie, X. (1999) Galloping of overhead transmission lines with bundled multiple-conductors. Proceeding of the 10th international conference of Wind Engineering,

Copenhagen/Denmark. 615-622.

Downloads

Published

2018-07-09

Issue

Section

Articles

How to Cite