ANALYTICAL STUDY OF NATURAL DRAUGHT COOLING TOWER ON VERTICAL PILES USING FINITE ELEMENT METHOD

Authors

  • N.V.Vamsee Krishna Department of Civil Engineering, JNTU, Kukatpally, Hyderabad, 500085, India
  • K. Rama Mohana Rao BICS, JNTU, Kukatpally, Hyderabad, 500085, INDIA

DOI:

https://doi.org/10.11113/mjce.v28.15972

Keywords:

Cooling towers, shell thickness, thermal power, vertical pile foundation, wind load

Abstract

The study aimed to analyse the behavior of natural draught cooling tower (NDCT) resting on a vertical pile foundation specifically focusing on prevailing soil conditions in the coastal areas. 27 different cases of shell thickness variation models are studied. The study adopted FEM analysis of NDCT and its foundation as a composite model which also facilitate to study the impact of providing a vertical pile foundation on the behavior of NDCT super structure. Results demonstrated that the reactions on all the piles are within the allowable pile capacities in all cases 1 to 27. In addition, our arc over which lift occurs in the foundation was 0º.The pile support reactions indicate that the horizontal loads on all the piles are varying based on the loads from the superstructure and when the NDCT super structure and its foundation were analysed with composite model.Maximum displacement of the shell and pile forces are reducing by increasing the top level of bottom ring beam.Further, our paper did show the deflection profile and pile reaction variation profile closer to realistic/actual behavior of NDCT than a conventional model.Therefore, the methodology adopted in this paper to study the behavior of 3D modeling of NDCT and its foundation could able to predict the dynamic responses of wind structure. From the results of the study it was established that in coastal areas NDCT can be supported on simple vertical piles instead of conventional raker piles. Further the study also identified optimum shell thickness profiles to be adopted to obtain the optimum foundation and the superstable structure for NDCT resting on vertical pile foundation.

References

Abedi-Nik, F., Sabouri-Ghomi, S., Santini, A., and Moraci, N. (2008). The Damaging Effects of

Earthquake Excitation on Concrete Cooling Towers. AIP Conference Proceedings 1020:

–778.

Angalekar, S.S., and Kulkarni, A. B. (2013). Analysis of Natural Draught Hyperbolic Cooling

Towers by Finite Element Method Using Equivalent Plate Concept. International Journal of

Engineering Research and Applications 1: 144–147.

Busch, D., Harte, R., Krätzig, W.B., and Montag, U. (2002). New natural draft cooling tower of

m of height. Engineering Structures 24: 1509–1521.

Gabrielaitis, L., and Papinigis, V. (2010). Design of Deep Foundations on Bored Piles. Modern

Building Materials, Structures and Techniques. 1104–1110. Vilnius, Lithuania: Vilnius

Gediminas Technical University.

IS 875(part 3):1987 (Reaffirmed 1997): Code of Practice for Design Loads (Other Than

Earthquake) For Buildings And Structures, Part 3 Wind Loads (Second Revision).

IS 11504:1985 (Reaffirmed 1998): Criteria for Structural Design of Reinforced Concrete Natural

Draught Cooling Towers.

Ke, S.T., Ge, Y.J., Zhao, L., and Tamura, Y. (2015). Stability and Reinforcement Analysis of

Superlarge Exhaust Cooling Towers Based on a Wind Tunnel Test. Journal of Structural

Engineering 141: 04015066.

Patil, G., Nema, M.K., Shrivastava, A., and Verma, U.S.P. (2007). Assessment of dynamic wind

effect and optimization of shell for tall NDCT using BS-4485 code approach. Proceedings

of the Fourth National Conference on Wind Engineering. India: SERC Chennai.

Radwańska, M. and Waszczyszyn, Z. (1995). Buckling analysis of a cooling tower shell with

measured and theoretically-modelled imperfections. Thin-Walled Structures 23: 107–121.

Ramanjaneyulu, K., Gopalakrishnan, S., and Appa Rao, T.V.S.R. (2003). Seismic response

analysis of column supported natural draught cooling tower shells. Proceedings of the

national seminar on seismic design of nuclear power plants 34: 461-473.

Singh, A., and Rajput, S.P.S. (2012). Thermal Performance Evolution of 2-D CFD Model of

Natural Draft Wet Cooling Tower. International Journal of Scientific & Engineering

Research 3: 1–6.

Zhang, W., Yang, H., Cui, P., Lu, L., Diao, N., and Fang, Z. (2015). Study on spiral source

models revealing groundwater transfusion effects on pile foundation ground heat

exchangers. International Journal of Heat and Mass Transfer 84: 119–129.

Downloads

Published

2018-07-16

Issue

Section

Articles

How to Cite

ANALYTICAL STUDY OF NATURAL DRAUGHT COOLING TOWER ON VERTICAL PILES USING FINITE ELEMENT METHOD. (2018). Malaysian Journal of Civil Engineering, 28(2). https://doi.org/10.11113/mjce.v28.15972