APPROPRIATE BASE STIFFNESS OF SMART BASE ISOLATION SYSTEM
DOI:
https://doi.org/10.11113/mjce.v30.16026Keywords:
Base isolation system stiffness, MR damper, clipped-optimal control algorithm, base drift.Abstract
In this paper, the effect of base stiffness on the performance of hybrid control system of base isolation system and magnetorheological (MR) damper has been studied and its appropriate base stiffness has been determined. Many researches have been proposed that in the structure controlled by the single base isolation system without MR damper, the base stiffness should be designed such that the fundamental period of isolated structure is almost triple the fundamental period of fixed-base structure. To determine the appropriate base stiffness of hybrid control system, different values have been considered as base stiffness and MR damper has been also employed in two cases of passive form that voltage and dynamical behaviour of MR damper is constant (hybrid base isolation) and semi-active form that MR damper voltage is applied by H2/linear quadratic Gaussian (LQG) and clipped-optimal control algorithms (smart base isolation). For numerical simulation, a three-story shear frame has been subjected to El Centro, Northridge and Tabas earthquakes. Results show that in the structure controlled by the single base isolation system, the peak responses of structure strongly depend on the base stiffness while the sensitivity of peak responses to the base stiffness is lower when the structure is controlled by hybrid base isolation system. According to results, it can be concluded that the peak base drift of hybrid base isolation system reduces with the increase of the base stiffness while this reduction trend is less considerable in the stiffness that are more than the proposed stiffness for the single base isolation system. Hence the proposed stiffness for single base isolation system is the appropriate stiffness for hybrid base isolation system, too. Results also show that under earthquakes considered in this paper, the smart base isolation system is mostly more effective than hybrid base isolation system in mitigating and controlling both root mean square and maximum of structure responses such as base drift, inter-story drift and acceleration.References
Bani-Hani, K.A., and Sheban, M.A. (2006) Semi-active neuro-control for base-isolation system using magnetorheological dampers. Earthquake Engineering and Structural Dynamics, 35: 1119-1144.
Bisch, P., Carvalho, E., Degee, H., and et al. (2012) Eurocode 8: seismic design of buildings worked examples. Luxembourg: JRC technical report, Publications Office of the European Union/Joint Research Centre.
Chen, P.C., Tsai, K.C., and Lin, P.Y. (2014) Real-time hybrid testing of a smart base isolation system. Earthquake Engineering and Structural Dynamics, 43: 139-158.
Constantinou, M.C., Symans, M.D., Tsopelas, P., and Taylor, D.P. (1993) Fluid dampers for application of seismic energy dissipation and seismic isolation. Proceeding of ATC-17-1 Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control.
Dadkhah, H., and Noruzvand, M. (2017) Optimal Response-Related Weighting Matrices to Control Semi-Active Base Isolation Systems. Slovak Journal of Civil Engineering, 25: 24-32.
Dyke, S.J., Spencer, B.F., Sain, M.K., and Carlson, J.D. (1996) Modeling and control of Magnetorheological dampers for seismic response reduction. Smart Materials and Structures, 5: 565-575.
Gu, X., Li, J., Li, Y., and Askari, M. (2016) Frequency control of smart base isolation system employing a novel adaptive magneto-rheological elastomer base isolator. Journal of Intelligent Material Systems and Structures, 27: 849-858.
Hwang, J.S., Hung, C.F., Huang, Y.N., and Wang, S.J. (2010) Design force transmitted by isolation system composed of lead-rubber bearing and viscous dampers. International Journal of Structural Stability and Dynamics, 10: 287-298.
Inaudi, J.A., and Kelly, J.M. (1993) Hybrid isolation systems for equipment protection. Earthquake Engineering and Structural Dynamics, 22: 297-313.
Jansen, L.M., and Dyke, S.J. (2000) Semi-active control strategies for MR damper: A comparative study. Journal of Engineering Mechanics, 126: 795-803.
Jung, H.J., Spencer, B.F., and Lee, I.W. (2003) Control of seismically excited cable-stayed bridge employing magnetorheological fluid dampers. Journal of Structural Engineering, 129: 873-883.
Kim , H.S., Chang, S., and Kang, J.W. (2015) Evaluation of microvibration control performance of a smart base isolation system. International Journal of Steel Structures, 15: 1011-1020.
Mohebbi, M., and Dadkhah, H. (2017) Multi-objective semi-active base isolation system. International Journal of Optimization in Civil Engineering, 7: 319-338.
Mohebbi, M., Dadkhah, H., and Dabbagh, H.R. (2017) A genetic algorithm-based design approach for smart base isolation systems. Journal of Intelligent Material Systems and Structures, doi: 10.1177/1045389X17733058.
Mohebbi, M., Dadkhah, H., and Shakeri, K. (2015) Optimal hybrid base isolation and MR damper. International Journal of Optimization in Civil Engineering, 5: 493-509.
Moon, S.J., Huh, Y.C., Jung, H.J., Jang, D.D., and Lee, H.J. (2011) Sub-optimal design procedure of valve-mode magnetorheological fluid dampers for structural control. KSCE Journal of Civil Engineering, 15: 867-873.
Naeim, F. and Kelly, J.M. (1999) Design of seismic isolated structure: from theory to practice. London: Wiley.
Narasinhan, S., and Nagarajaiah, S. (2005) A STFT semi active controller for base isolated buildings with variable stiffness isolation systems. Engineering Structures, 27: 514-523.
Ramallo, J.C., Johnson, E.A., and Spencer, B.F. (2002) Smart base isolation systems. Journal of Engineering Mechanics, 128: 1088-1099.
Sahasrabudhe, S., and Nagarajaiah, S. (2005) Experimental study of sliding base-isolation buildings with Magneto-rheological Dampers in near-fault earthquake. Journal of Structural Engineering, 131: 1025-34.
Spencer, B.F., Dyke, S.J., Sain, M.K., and Carlson, J.D. (1997) Phenomenological model of a Magnetorheological damper. Journal of Engineering Mechanics, 123: 230-238.
Villaverde, R. (2009) Fundamental concepts of earthquake engineering. New York: Taylor and Francis group.
Wang, Y., and Dyke, S.J. (2013) Modal-based LQG for smart base isolation system design in seismic response control. Structural Control and Health Monitoring, 20: 753-768.
Wongprasert, N., and Symans, M.D. (2005) Experimental evaluation of adaptive elstomeric base-isolated structures using variable-orifice fluid dampers. Journal of Structural Engineering, 131: 867-877.
Yang, J.N., Wu, J.C., Reinhorn, A.M., and Riley, M. (1996) Control of sliding-isolated buildings using sliding-mode control. Journal of Structural Engineering, 122: 179-186.
Yoshioka, H., Ramallo, J.C., and Spencer, B.F. (2002) Smart base isolation strategies employing Magnetorheological Dampers. Journal of Engineering Mechanics, 128: 540-551