Self compacting concrete, fiber reinforced concrete, glass fiber reinforced self compacting concrete, workability, alkaline-resistance glass fiber, flexural strength, tensile strength.Abstract
Self Compacting Concrete (SCC) is a concrete that is able to flow under its own weight and completely fill the formwork, even in the presence of congested reinforcement, without any compaction, while maintaining homogeneity of the concrete. The elimination of compaction for SCC is beneficial in solving difficult casting conditions and reduction in manpower required. SCC was added with relatively short, discrete, and discontinuous glass fibers to produce Glass Fiber Reinforced Self Compacting Concrete (GFRSCC). Water-cement (w/c) ratio of 0.40 was used in concrete mix proportions. The fiber used was alkaline-resistance glass fiber. Three volume percentages of fiber were added to the mix, i.e. 0.5%, 1.0%, and 1.5% by volume of concrete. Workability and mechanical properties of the concrete were evaluated. SCC and GFRSCC were highly workable than normal concrete (NC). The dosage of superplasticizer required increment as fiber content increase. SCC exhibits higher compressive strength than NC and GFRSCC. Inclusion of fibers does not give positive effect to the compressive strength of GFRSCC. The splitting tensile strength of NC was higher than SCC and GFRSCC due to the negative influence of superplasticizer added. Results indicated that the flexural strength of NC was slightly higher than SCC. The flexural strength of GFRSCC was higher than SCC. The optimum fiber content for GFRSCC, determined during the study was 1.0% by volume of concrete. GFRSCC slab developed higher first crack load and ultimate load compared to NC and SCC slabsReferences
Awal A.S.M.A, Yee L.L. and Hossain M.Z. (2013) Fresh And Hardened Properties Of Concrete Containing Steel Fibre From Recycled Tire. Malaysian Journal of Civil Engineering Vol.25(1) pp.20-32 (2013)
Bartos, P. (1992). “Fresh Concrete – Properties and Tests.†ELSEVIER SCIENCE PUBLISHERS B.V., Amsterdam, The Netherlands.
BIBM, CEMBUREAU, ERMCO, EFCA, and EFNARC (2005) “The European Guidelines for Self-Compacting Concrete – Specification, Production and Use.â€.
British Standard Institute (BSI) (2009) BS EN 197-1: 2009. Cement Part 1: Composition, specifications and conformity criteria for common cements. London.
British Standard Institute (BSI) (1986) BS 1881-203: 1986. Testing fresh concrete Part 2: Slumptest. London.
British Standard Institute (BSI) (2009) BS EN 197-1: 2009. Testing concrete Part 203: Recommendations for measurement of velocity of ultrasonic pulses in concrete. London.
British Standard Institute (BSI) (2009) BS EN 12390-3: 2009. Testing hardened concrete Part 3: Compressive strength of test specimens. London.
British Standard Institute (BSI) (2009) BS EN 12390-6: 2009. Testing hardened concrete Part 6: Tensile splitting strength of test specimens. London.
British Standard Institute (BSI) (2009) BS EN 12390-5: 2009. Testing hardened concrete Part 5: Flexural strength of test specimens. London.
Choo, B.S. (2003). “Advance Concrete Technology Processes.†Edited by Newman, J.Butterworth-Heinemann, an imprint of Elsevier, Linear House, Jordan Hill, Oxford OX28DP, 200 Wheeler Road, Burlington MA 01803.
Ding, Y., Zhang, Y., and Thomas, A. (2009). “The Investigation on Strength and FlexuralToughness of Fibre Cocktail Reinforced Self-compacting High Performance Concrete.†Construction and Building Materials Volume 23, 2009, pg. 448-452.
Domone, P. L. (2006). “Self-Compacting Concrete: An Analysis of 11 Years of Case Studies.†Cement and Concrete Composites, Volume 28 (2006), pp. 197-208EFNARC (2002)
“Specification and Guidelines for Self-Compacting Concrete February 2002.â€
EFNARC, (2002), „Specification and Guidelines for Self -Compacting Concrete )
Gambhir, M.L. (2004). “Concrete Technology Third Edition.†Tata McGraw-Hill Publishing Company Limited, New Delhi.
Ken, W.D. (2006). “Concrete Mix Design, Quality Control and Specification.†Taylor and Francis, 2 Park Square, Milton Park, Abingdon, Oxon OX14 4RN.
Máca P., Sovják R. & Konvalinka P. (2013) Mixture Design and Testing Of Ultra High Performance Fiber Reinforced Concrete. Malaysian Journal of Civil Engineering Vol.25 Special Issue(1) pp.74-87 (2013)
Mazaheripour, H., Ghanbarpour, S., Mirmoradi, S.H., and Hosseinpour, I. (2010). “The effect of polypropylene fibers on the properties of fresh and hardened lightweight selfcompacting
concrete.†Construction and Building Materials Volume 25, Issue 1, 2010, pg. 351-358.
Mindess, S., Francis, J.Y., and Darwin, D. (2003). “Concrete Second Edition.†Pearson Education, Inc. Upper Saddle River, New Jersey.
Mirza, F.A., and Soroushian, P. (2002). “Effects of Alkali-Resistant Glass Fiber Reinforcement on Crack and Temperature Resistance of Lightweight Concrete.†Cement and Concrete
Composites, Volume 24, Issue 2, April 2002, pp. 223-227.
Neville, A.M. (1995). “Properties of Concrete – Fourth and Final Edition.†Addison Wesley Longman Limited, Edinburgh Gate, Harlow, Essex CM20, 2JE, England.
Parra, C., Valcuende, M., and Gomez, F. (2011). “Splitting Tensile Strength and Modulus of
Elasticity of Self-Compacting Concrete.†Construction and Building Materials, Volume 25, Issue 1, January 2011, pp. 201-207.
Shetty, M.S. (2006). “Concrete Technology-Theory and Practice.†S. Chand and Company LTD., New Delhi.
Sivakumar, A., and Santhanam, M. (2007). “Mechanical Properties of High Strength Concrete Reinforced with Metallic and Non-Metallic Fibers.†Cement and Concrete Composites,
Volume 29, March 2007, pp. 603-608.
Torrijos, M.C., Barragan, B.E., and Zerbino, R.L. (2007). “Physical-mechanical Properties, and Mesostructure of Plain and Fibre Reinforced Self Compacting Concrete.†Construction
and Building Materials Volume 22, Issue 8, August 2008, pg. 1780-1788.