PERFORMANCE OF REINFORCED CONCRETE HOSPITAL BUILDING SUBJECTED TO EARTHQUAKE USING BASE-ISOLATION SYSTEM
DOI:
https://doi.org/10.11113/mjce.v28.15974Keywords:
Durability, High strength concrete, Steel slag aggregate, RCC hospital building, non-linear static analysis, seismic capacity and baseisolation.Abstract
The frequent occurrence of earthquake in the Bangladesh and up-gradation of seismic design code (BNBC-1993) has heightened the need for investigation of seismic performance of existing lifeline structure specially hospital building. The objective of this study is to evaluate seismic capacity and corresponding improvement of an existing hospital building (Ancillary Building) of Chittagong Medical College Hospital (CMCH). For this purpose, a three dimension (3-D) numerical model of Ancillary Building (AB) of CMCH was developed using SAP 2000 finite element program. A non-linear static analysis was performed to determine seismic capacity of the building model. The result indicates the seismic capacity of the hospital building is sufficient to mitigate the seismic demand according to BNBC-1993, whereas the seismic capacity is found insufficient as per revised BNBC. To reduce the seismic effect on AB, base-isolation devices have been designed and were used as link element to the numerical model. The application of base-isolation devices as a retrofitting strategy makes the considered hospital building safer for seismic excitation suggested in revised BNBC.References
AS11704, (1993). Australian Building Code.
ATC-40, (1996). Seismic Evaluation and Retrofit of Concrete Buildings.
BNBC, (1993). Bangladesh National Building Code, Housing and Building Research
Institute.
Buckle, I.G., and Mayes, R.L, (1990). Seismic Isolation: History, application and performance A
world review, Earthquake Spectra, 6: 2: 161-201.
EC-8, (2004). Eurocode-8 Seismic Design Euro Code.
FEMA-356, (2000). Report on the Pre standard and commentary for the Seismic
Rehabilitation of Buildings.
Hasan, M.A., (2015). Assessment of Seismic Fragility and Retrofit of Hospital Building
using Base-isolation Devices. M.Sc Dissertation, Chittagong University of
Engineering and Technology, Bangladesh.
Hasan, M. A., and Bhuiyan, R. A., (2014). Seismic Performance Evaluation of Seismically
Isolated Reinforced Concrete Building: A Case Study.2
nd International Conference
on Advances in Civil Engineering (ICACE-2014) on 26-28 December, 2014, pp.
-637, CUET, Bangladesh.
Hasan, M. A., and Bhuiyan, R. A., (2015). Fragility Assessment of an Existing Reinforced
Concrete Hospital Building. 1st National Conference on Earthquake and Environmental
Disaster on 17 December, 2015, pp. 26-32, CUET, Bangladesh.
Huang, H., and Li, W., (2008). Research on development and distribution rules of geohazard
induced by wenchan earthquake, 12th Chinese Journal of rock mechanics
and engineering 27(12):2585-2595.
Japan Road Association, (2002). Specification for highway bridges - part V:Seismic design,
Tokyo, Japan.
Kelly, J.M., (1997). Earthquake Resistant Design with Rubber, 2nd Edition, SpringerVerlag
Berlin Heidelberg, New York.
Nagarajaiah, S., Reinhorn, A.M., and Constantinou, M.C., (1991). Nonlinear dynamic
analysis of 3–D base isolated structures, Journal of Structural Engineering, ASCE,
Vol. 117, pp. 2035– 2054.
NZS 4203, (1992). New Zealand Building Code.
Park, Y.J., Wen, Y.K., and Ang, A.H.S.(1986). Random vibration of hysteretic systems
under bi-directional ground motions, Earthquake Engineering and Structural
Dynamics, Vol. 14, pp. 543-557.
Stafford, S.B., (1966). Behavior of square In-Filled Frames. Journal of the structural
Division, ASCE, vol.92.