THE INFLUENCE OF FEMORAL BALL SIZE ON THE RANGE OF MOTION THAT FULFILLS THE CRITERIA OF SAFE ZONE ORIENTATION ACETABULAR CUP
DOI:
https://doi.org/10.11113/jt.v76.5711Keywords:
Acetabular cup, orientation, range of motion, dislocation, edge loadingAbstract
Dislocation and edge loading are significant issues highlighted due to the acetabular component orientation during total hip replacement(THR). This study aims to define the optimum acetabular cup orientation with the most suitable femoral ball size, thus eliminating the possible issue that may arise during postoperative surgery. A numerical approach by creating a single function that enables the calculation of the cup inclination (α) and the cup anteversion (β) with respect to range of motion are developed by using a programming language namely Matlab®. Three separate studies were done by having a head neck ratio of 2.33, 2.67 and 3.0, respectively. From these data, it is clear that the size of femoral head affects the area under range of motion at the bearing surfaces. A wide area under the graph resulted in a better and greater number combination of acetabular cup thus reducing the risk of dislocation and edge loading.
References
Mattei, L., Di Puccio, F., Piccigallo, B. and Ciulli, E. 2011. Lubrication And Wear Modelling Of Artificial Hip Joints: A review. Tribol. Int. 44(5): 532–549.
Epstein, M., Emri, I., Hartemann, P., Hoet, P., Leitgeb, N., Martinez, A., Proykova, L., Rizzo, E., Rodriguez-Farre, L., Rushton, L. M., Rydzynski, K., Samaras, T., Testai, E. and Vermeire, T. 2014. Scientific Committee on Emerging and Newly Identified Health Risks SCENIHR Opinion on The safety of Metal-on-Metal joint replacements with a particular focus on hip implants.
Holzwarth U. and Cotogno, G. 2012. Total Hip Arthroplasty: State of the Art, Challenges and Prospects.
Ko B.-H. and Yoon, Y.-S. 2008. Optimal Orientation Of Implanted Components In Total Hip Arthroplasty With Polyethylene On Metal Articulation. Clin. Biomech. (Bristol, Avon). 23(8): 996–1003.
Kummer, F. J., Shah, S., Iyer, S. and DiCesare, P. E.1999. The Effect of Acetabular Cup Orientations on Limiting Hip Rotation. The Journal of Arthroplasty. 14(4): 509–513.
Little, N. J., a Busch, C., a Gallagher, J., Rorabeck, C. H. and Bourne, R. B. 2009. Acetabular Polyethylene Wear And Acetabular Inclination And Femoral Offset. Clin. Orthop. Relat. Res. 467(11): 2895–2900.
Hua, X., Wroblewski, B. M., Jin, Z. and Wang, L. 2012. The Effect Of Cup Inclination And Wear On The Contact Mechanics And Cement Fixation For Ultra High Molecular Weight Polyethylene Total Hip Replacements. Med. Eng. Phys. 34(3): 318–325.
Yoon, Y.-S., Hodgson, A. J., Tonetti, J., a Masri, B. and Duncan, C. P. 2008. Resolving Inconsistencies In Defining The Target Orientation For The Acetabular Cup Angles In Total Hip Arthroplasty. Clin. Biomech. (Bristol, Avon). 23(3): 253–259.
Yoshimine, F. and Ginbayashi, K. 2002. A Mathematical Formula To Calculate The Theoretical Range Of Motion For Total Hip Replacement. J. Biomech. 35(7): 989–993.
Yoshimine, F. 2006. The Safe-Zones For Combined Cup And Neck Anteversions That Fulfill The Essential Range Of Motion And Their Optimum Combination In Total Hip Replacements. J. Biomech.39(7): 1315–1323.
Widmer, K.-H. and Majewski, M. 2005. The Impact Of The CCD-Angle On Range Of Motion And Cup Positioning In Total Hip Arthroplasty. Clin. Biomech. (Bristol, Avon). 20(7): 723–728.
Yoshimine, F. 2005. The Influence Of The Oscillation Angle And The Neck Anteversion Of The Prosthesis On The Cup Safe-Zone That Fulfills The Criteria For Range Of Motion In Total Hip Replacements. The Required Oscillation Angle For An Acceptable Cup Safe-Zone. J. Biomech. 38(1): 125–132.
Klingenstein, G. G., Yeager, A. M., Lipman, J. D. and Westrich, G. H. 2013. Computerized Range Of Motion Analysis Following Dual Mobility Total Hip Arthroplasty, Traditional Total Hip Arthroplasty, And Hip Resurfacing. J. Arthroplasty. 28(7): 1173–1176.
Widmer, K.-H.and Zurfluh, B. 2004. Compliant Positioning Of Total Hip Components For Optimal Range Of Motion. J. Orthop. Res. 22(4): 815–821.
Ji, W.-T., Tao, K. and Wang, C.-T. 2010. A Three-Dimensional Parameterized And Visually Kinematic Simulation Module For The Theoretical Range Of Motion Of Total Hip Arthroplasty. Clin. Biomech. (Bristol, Avon). 25(5): 427–432.
Widmer, K.-H.2003. Comment On 'A Mathematical Formula To Calculate The Theoretical Range Of Motion For Total Hip Arthroplasty.' J. Biomech. 36(4): 615.
Matsushita, A., Nakashima, Y., Jingushi, S., Yamamoto, T., Kuraoka, A. and Iwamoto, Y. 2009. Effects Of The Femoral Offset And The Head Size On The Safe Range Of Motion In Total Hip Arthroplasty. J. Arthroplasty. 24(4): 646–651.
Miki, H., Kyo, T., Kuroda, Y., Nakahara, I. and Sugano, N. 2014. Risk Of Edge-Loading And Prosthesis Impingement Due To Posterior Pelvic Tilting After Total Hip Arthroplasty. Clin. Biomech. (Bristol, Avon). 29(6): 607–613.
Downloads
Published
Issue
Section
License
Copyright of articles that appear in Jurnal Teknologi belongs exclusively to Penerbit Universiti Teknologi Malaysia (Penerbit UTM Press). This copyright covers the rights to reproduce the article, including reprints, electronic reproductions, or any other reproductions of similar nature.