BEHAVIOR OF IMPLANT STABILITY DURING IMPLANT TREATMENT: IN VIVO STUDY
DOI:
https://doi.org/10.11113/jt.v76.5714Keywords:
Implant stability, bone quality and quantity, implant insertionAbstract
Implant stability is essential parameters that indicate the success of the implant treatment. However, the relation between implant stability, osseointegration and also remodeling process during that period is still unclear. This study was to evaluate the behavior of implant stability during implant treatment period.To investigate the behavior of the implant stability and its relation with quality and quantity of the bone during implant treatment, eight dental implant patients have been involved. Series of monitoring stages were conducted. The implant stability for each stage were measured using Resonance Frequency Analysis (RFA) devise and the behavior of quality and quantity of the bone during treatment have been monitored by using CBCT data. The phases of monitoring are divided into 3 phases; phase 1 is immediately after implant insertion, phase 2 is immediately after crown installation (4 month after implant insertion), and phase 3 is 1 month after crown installation (5 month after implant insertion). The results were tabulated and analyzed using statistical software namely SPSS 20.5 to examine the correlation between basic measurement of bone quality and quantity and ISQ. The results show that during 4 month after implant insertion period, the density of bone around the implant are decrease, this period was predicted as remodeling process. After 5 moth since implant insertion, the density start to increase. This phase possibly indicated the starting phase of osseointegration process. In addition, the ISQ for each patient was increased significantly. The primary implant stability was correlated with the space availability and bone quantity and quality, the result shows that the implant stability is proportional with the height of the mandibular and cortical thickness and inversely with width of mandibular. The highest correlation with the primary implant stability is the product of cortical thickness with the height of mandibular. There is a significant correlation between implant stability (ISQ) with dimension of site implant and density of bone. Â
References
Oliscovicz, N. F., Shimano, A. C., Marcantonio Junior, C., Lepri, P. and Dos Reis, A. C. 2013. Analysis Of Primary Stability Of Dental Implants Inserted In Different Substrates Using The Pullout Test And Insertion Torque. Int. J. Dent.
Brouwers, J. E. I. G., Lobbezoo, F., Visscher, C. M., Wismeijer, D. and Naeije, M. 2009. Reliability And Validity Of The Instrumental Assessment Of Implant Stability In Dry Human Mandibles. J. Oral Rehabil. 36: 279–283.
Barikani, H., Rashtak, S., Akbari, S., Fard, M. K. and Rokn, A. 2014. The Effect Of Shape, Length And Diameter Of Implants On Primary Stability Based On Resonance Frequency Analysis. Dent. Res. J. (Isfahan). 11(1): 87–91.
Farre-Pages, N., Auge-Castro, M., Alaejos-algarra, F., Mareque-Bueno, J., Ferres-Padro, E., Hernandez-Alfaro, F. , Farré-pagès, N., Augé-castro, M. L. and Hernández-alfaro, F. 2011. Relation Between Bone Density And Primary Implant Stability. Med. Oral Patol. Oral y Cir. Bucal. 16(1): e62–e67.
Isoda, K., Ayukawa, Y., Tsukiyama, Y., Sogo, M., Matsushita, Y. and Koyano, K. 2011. Relationship Between The Bone Density Estimated By Cone-Beam Computed Tomography And The Primary Stability Of Dental Implants. Clin. Oral Implants Res.1–5.
Merheb, J., Van Assche, N., Coucke, W., Jacobs, R., Naert, I. and Quirynen, M. 2010. Relationship Between Cortical Bone Thickness Or Computerized Tomography-Derived Bone Density Values And Implant Stability. Clin. Oral Implants Res. 21(6): 612–617.
Lin, D., Li, Q., Li, W., Ichim, I. and Swain, M. 2002. Evaluation Of Dental Implant Induced Bone Remodelling By Using A 2D Finite Element Model. Australas. Congr. Appl. Mech. 0–5.
Santos, M. C. L. G., Campos, M. I. and Line, S. R. 2002. Early Dental Implant Failure : A review of the literature. Braz J Oral Sci. 1(3): 103–111.
Downloads
Published
Issue
Section
License
Copyright of articles that appear in Jurnal Teknologi belongs exclusively to Penerbit Universiti Teknologi Malaysia (Penerbit UTM Press). This copyright covers the rights to reproduce the article, including reprints, electronic reproductions, or any other reproductions of similar nature.