PRE-CONCENTRATION AND DETERMINATION OF PB(II) FROM WATER SAMPLES USING MODIFIED MULTIWALLED CARBON NANOTUBES

Authors

  • Neda Pourmand Deparment of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Mohd Marsin Sanagi Ibnu Sina Institute for Scientific and Industrial Research, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Wan Aini Wan Ibrahim Ibnu Sina Institute for Scientific and Industrial Research, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Ahmed Salisu Ibnu Sina Institute for Scientific and Industrial Research, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia

DOI:

https://doi.org/10.11113/jt.v76.5817

Keywords:

Multiwalled carbon nanotubes, Solid phase extraction, Pre-concentration, Pb(II), Heavy metal ions

Abstract

Pb(II) is a topically poisonous metal ion that can affect almost every organ and system in the body; it can accumulate in the body and cause kidney malfunctioning, hematological and brain damages. Recently, carbon nanotubes (CNTs), the nano-structured material, are applied for pre-concentration of heavy metal ions. This study investigates the pre-concentration of lead ion using oxidized multiwalled carbon nanotubes (MWCNT-COOH) via solid phase extraction method. MWCNT-COOH was prepared using as-synthesized MWCNT and the products were characterized by FTIR, FESEM, TEM and TGA. Various factors influencing the separation and pre-concentration were investigated namely the effects of pH (2-7) and the elution conditions (type, concentration and volume of eluent). The best extraction conditions were sample of pH 5 and 5 mL of 1M HNO3 as eluent. The developed method was successfully applied to the determination of trace quantities of Pb(II) in water samples with good analyte recoveries (90-102.5%). 

References

Kozlowska, J., Kozlowski, C.A. and Koziol, J. J. 2007. Sep. Purif. Technol. 57: 430.

Baran, A., Bicak, E., Baysal, S. H., Onal Bioresour S. 2006. Technol. 98: 661.

Sweileh, J. A. and El-Nemma, E. M. 2004. Anal. Chim. Acta. 523: 287.

Lee, S. H. and Choi, Bull. Korean, H. S. B. 2003. Chem. Soc. 24: 1705.

Kara, D. and Tekin, N. Microchim. 2005. Acta. 149: 193.

Her, G., Choi, H.S. and Korean, J. 2005. Chem. Soc. 49: 145.

Iijima, S. and Ichihashi, T. 1993. Single-shell Carbon Nanotubes of 1-nm Diameter. Nature. 363: 603.

Wang, L., Liu J. M., Zhao, P., Ning, Z. W., and Fan, H. L. 2010. J. Chromatogr. A. 37: 5741.

Li, R., Chang, X., Zang, Z., Hu, Z. Li, D. and Tu, Z. 2011. Microchim. Acta. 172: 262.

Stalikas. C. D. 2003. Trends Anal. Chem. 21: 343.

Long, R. Q. and Yang, R. T. 2001. J. Am. Chem. Soc. 123: 2058.

Li, Y. H., Zhu, Y. Q. and Zhao, Y. M. 2006. Diamond. Relat. Mater. 15: 90.

Lu, C. and Chung, Y. L. 2005. Water Res. 39: 1183.

Ren, X. M., Chen, C. L., Nagatsu, M. and Wang, X. K. 2011. Chem. Eng. J. 170: 395.

Downloads

Published

2015-10-13

How to Cite

PRE-CONCENTRATION AND DETERMINATION OF PB(II) FROM WATER SAMPLES USING MODIFIED MULTIWALLED CARBON NANOTUBES. (2015). Jurnal Teknologi, 76(13). https://doi.org/10.11113/jt.v76.5817