DOUBLE SHEAR TEST BEHAVIOUR OF BALAU SPECIES FOR DIFFERENT END DISTANCE

Authors

  • Nor Jihan Abd Malek Faculty of Civil Engineering, MARA University of Technology, 40450 Shah Alam, Selangor, Malaysia
  • Rohana Hassan Faculty of Civil Engineering, MARA University of Technology, 40450 Shah Alam, Selangor, Malaysia
  • Elamin Mohamed Ali Faculty of Civil Engineering, MARA University of Technology, 40450 Shah Alam, Selangor, Malaysia
  • Mohd Nizam Shakimon Faculty of Civil Engineering, MARA University of Technology, 40450 Shah Alam, Selangor, Malaysia

DOI:

https://doi.org/10.11113/jt.v78.8556

Keywords:

Timber, double shear, connection, end distance, EYM

Abstract

Timber connection is the most important part in timber structural building. In design, it depends on parameter criteria such as bolt diameter, bolt spacing, edge and end distance. End distance is one of design criteria that will influence mechanical timber joint such in single and double shear. This study focuses for a single fastener joint loaded in double shear with 12mm and 16mm bolt diameters having 30mm and 40mm end distance respectively. Double shear test was conducted on Balau timber species and the finding also focuses on the pattern failure modes with reference to European Yield Model (EYM) theory according to National Design Specification (NDS) 2005. It shows that the joint ability to withstand load decreased when the bolt diameter and end distance smaller and conversely with larger bolt diameter. The failure behavior for 12mm diameter tends to fail into category IIIs which described two plastic hinges formed with crushing of wood fibres in the side members. While, 16mm diameter bolt tends to fail under categories of mode Is which dowel bearing failure or crushing of the side members. Eventually, 12mm bolt diameter produces lower shear strength compared to 16mm bolt diameter. 

References

National Design Specification for Wood Construction (NDS). 2005. American Forest and Paper Association (AFPA) Washington D.C.

Kiwelu, H. 2013. Finite Element Models of Effects of Moisture on Bolt Embedment and Connection Properties of Glulam.

Gattesco, N. & Toffolo, I. 2004. Experimental Study On Multiple-Bolt Steel-To-Timber Tension Joints. Materials And Structures. 129-138. BF02486609.

Staneva, N. & Sokolovski, S. Special Features of Design of Bolted Joints For Timber Structures. mdesign.ftn.uns.ac.rs: 333-336.

Stehn, L., & Johansson, H. 2002. Ductility Aspects in Nailed Glue Laminated Timber Connection Design. 382-389.

Burnett, D. T., Clouston, P., Damery, D. T. and Fisette, P. 2003. Structural Properties Of Pegged Timber Connections As Affected By End Distance. 53(9303): 50-57.

Wilkinson, T. L. 1993. Bolted Connection Strength And Bolt Hole Size.

Malaysian Standard, Code of Practice for Structural Use of Timber. 2001. Part 5, Timber Joints, Malaysia, MS544.

Zarnani, P. & Quenneville, P., 2012. Consistent Yield Model For Strength Prediction Of Timber Rivet Connection Under Ductile Failure. 12th World Conference on Timber.

BS EN 1993-1-8:2005(E). 2011. Eurocode 3: Design of Steel Structures: Design of joints. 8(2005).

Hassan, R., Ibrahim A., and Ahmad, Z. Experimental Performance of Mortice and Tenon Joint Strengthened with Glass Fibre Reinforced Polymer under Tensile Load. DOI:10.1109/ISBEIA.2012.6423013.

Hassan, R., Ibrahim A., and Ahmad, Z. 2011. Estimation of Double Shear Strength of Timber Connections Fastened with Glass Fibre Reinforced Polymer Dowel by National Design Specification. 5(1): 1-10.

Connections, T., Schmidt, R. J., Daniels, C. E., Frame, T. and Council, B. 1999. Design Considerations For Mortise And Tenon Connections. 272(20).

Downloads

Published

2016-05-09

Issue

Section

Science and Engineering

How to Cite

DOUBLE SHEAR TEST BEHAVIOUR OF BALAU SPECIES FOR DIFFERENT END DISTANCE. (2016). Jurnal Teknologi, 78(5-4). https://doi.org/10.11113/jt.v78.8556